University of Massachusetts, Lowell, 1 University Ave., OL122, Lowell, MA 01854, USA.
J Biophotonics. 2013 Sep;6(9):679-86. doi: 10.1002/jbio.201200102. Epub 2012 Sep 25.
Intra-operative delineation of breast cancer is a challenging problem. We used dye-enhanced wide-field polarization imaging for rapid demarcation of en face cancer margins and optical coherence tomography (OCT) for cross-sectional evaluation. Ductal carcinoma specimens were stained with methylene blue. Wide-field reflectance images were acquired at 440 and 640 nm. Wide-field fluorescence images were excited at 640 nm and registered between 660 nm and 750 nm. OCT images were acquired using a 1310 nm swept-source system. The results were validated against histopathology. Both imaging modalities provided diagnostic information on cancer margins. Combined OCT and wide-field polarization imaging shows promise for intra-operative detection of ductal breast carcinoma.
术中乳腺癌的描绘是一个具有挑战性的问题。我们使用染料增强的广角偏振成像技术快速划定肿瘤边界,并使用光学相干断层扫描(OCT)进行横截面评估。将乳腺癌组织用亚甲蓝染色。在 440nm 和 640nm 处采集广角反射图像。用 640nm 激发广角荧光图像,并在 660nm 和 750nm 之间记录。使用 1310nm 扫频源系统采集 OCT 图像。结果与组织病理学相对照。两种成像方式均提供了有关癌症边界的诊断信息。结合 OCT 和广角偏振成像有望用于术中检测乳腺导管癌。