Faculty of Environmental Studies, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia.
J Chromatogr A. 2012 Nov 2;1262:160-8. doi: 10.1016/j.chroma.2012.09.024. Epub 2012 Sep 16.
A multi-residue analytical method was developed to quantify nine antibiotics and one hormone in soil, broiler manure and manure compost. The developed method was based on ultrasonic extraction with MeOH:ACN:EDTA:McIlvaine buffer, solid phase extraction (SPE) using HLB (3 cc/60 mg) cartridge, followed by instrumental analysis using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with 25 min total run time. It was validated and tested on soil, broiler manure and manure compost samples and showed that the method is able to simultaneously detect and quantify the target analytes with good selectivity and sensitivity. The developed method was linear in a concentration range from its instrumental quantification limit (IQL) to 500 ng/mL, with correlation coefficients higher than 0.999. The overall method performance was good for the majority of the analytes, with recoveries range from 63% to 121% in all the sample matrices. The method quantification limit (MQL) for the 10 target analytes in the soil, broiler manure and manure compost samples were 2-10, 3-16 and 5-15 μg/kg dry weight (DW), respectively. The method has also included tilmicosin, an antibiotic known to be reported in the environment for the first time. The developed method was then applied on broiler manure samples and its relative manure amended agricultural soil samples to identify and quantify veterinary antibiotic and hormone residues in the environment. These analytes were detected in broiler manure and soil samples, with maximum concentrations reaching up to 78516.1 μg/kg DW (doxycycline) and 1331.4 μg/kg DW (flumequine), respectively. The results showed that the method can potentially be adopted for the analysis of veterinary antibiotic and hormone wastes in solid environmental matrices.
建立了一种多残留分析方法,用于定量检测土壤、鸡粪和堆肥中的九种抗生素和一种激素。该方法基于甲醇:乙腈:EDTA:McIlvaine 缓冲液的超声提取,使用 HLB(3 cc/60 mg)柱的固相萃取(SPE),随后使用液相色谱-串联质谱(LC-MS/MS)进行仪器分析,总运行时间为 25 min。该方法经过验证并应用于土壤、鸡粪和堆肥样品,结果表明该方法能够同时检测和定量目标分析物,具有良好的选择性和灵敏度。该方法在仪器定量限(IQL)至 500 ng/mL 的浓度范围内呈线性关系,相关系数均高于 0.999。对于大多数分析物,该方法的整体性能良好,在所有样品基质中的回收率范围为 63%至 121%。该方法在土壤、鸡粪和堆肥样品中 10 种目标分析物的定量限(MQL)分别为 2-10、3-16 和 5-15 μg/kg 干重(DW)。该方法还包括替米考星,这是一种首次在环境中报道的抗生素。然后将该方法应用于鸡粪样品及其相对的施粪农业土壤样品中,以鉴定和定量环境中的兽用抗生素和激素残留。在鸡粪和土壤样品中检测到这些分析物,最高浓度分别达到 78516.1 μg/kg DW(强力霉素)和 1331.4 μg/kg DW(氟甲喹)。结果表明,该方法有可能被用于分析固体环境基质中的兽用抗生素和激素废物。