Tani Y, Ishihara T
Laboratory of Experimental Pharmacology, Suntory Institute for Biomedical Research, Osaka, Japan.
Life Sci. 1990;46(5):373-8. doi: 10.1016/0024-3205(90)90017-l.
This report describes a rapid and sensitive method for measuring tetrahydrobiopterin (THBP) and biogenic amines simultaneously by liquid chromatography with electrochemical detection (LC-ECD). The coefficient of variation for THBP was 4.87% and the minimum detectable amount of THBP was approximately 20 pg. These results indicate that this simple reverse-phase ion-pair chromatography system can be used for the simultaneous analysis of endogenous THBP and biogenic amines without long sample preparation time.
本报告描述了一种通过液相色谱-电化学检测法(LC-ECD)同时测量四氢生物蝶呤(THBP)和生物胺的快速灵敏方法。THBP的变异系数为4.87%,THBP的最低检测量约为20皮克。这些结果表明,这种简单的反相离子对色谱系统可用于同时分析内源性THBP和生物胺,且无需长时间的样品制备。