Chandrasekhar B, Prayaga Aruna K
Department of Pathology, Nizams Institute of Medical Sciences, Hyderabad, India.
J Cytol. 2012 Jul;29(3):165-8. doi: 10.4103/0970-9371.101160.
Microscopy detection of acid fast bacilli (AFB) by Ziehl-Neelsen (ZN) method has many advantages when it comes to speed and feasibility though it has a low sensitivity. If the sensitivity could be improved, it has the potential to become an even more valuable tool for detection of AFB.
To evaluate the efficacy of bleach concentration method in the cytodiagnosis of tuberculous lymphadenitis in comparison with routine Ziehl-Neelsen method and to compare the positivity in various cytomorphological categories.
A total of 112 cases of tuberculous lymphadenitis diagnosed by fine needle aspiration cytology (FNAC) were categorized into six cytomorphological patterns. The acid-fast bacilli positivity by routine staining was correlated with modified bleach methods of ZN staining. Sensitivity of routine ZN and modified bleach concentration was compared.
The classic cytomorphological pattern of tuberculosis of epithelioid granulomas, langhans giant cells and caseous necrosis was seen in 37.5% of cases. Routine ZN staining detected AFB in 12.5% of cases and the modified bleach method in 60.7%. Modified bleach method showed AFB positivity in additional 54 cases where routine AFB staining was negative. The modified bleach method showed AFB positivity in all cases where routine ZN staining was positive.
The modified bleach method was more sensitive and safer than routine ZN staining. As the background was clear, the bacilli were easily visible and the screening time was shorter.
萋-尼(ZN)法显微镜检测抗酸杆菌(AFB),尽管灵敏度较低,但在速度和可行性方面有诸多优势。如果能提高其灵敏度,它有可能成为检测AFB更有价值的工具。
与常规萋-尼法相比,评估漂白剂浓缩法在结核性淋巴结炎细胞诊断中的效果,并比较不同细胞形态学类别的阳性率。
将112例经细针穿刺细胞学检查(FNAC)诊断为结核性淋巴结炎的病例分为六种细胞形态学模式。将常规染色的抗酸杆菌阳性结果与改良的ZN染色漂白剂方法进行关联。比较常规ZN法和改良漂白剂浓缩法的灵敏度。
37.5%的病例出现了上皮样肉芽肿、朗汉斯巨细胞和干酪样坏死的典型结核细胞形态学模式。常规ZN染色在12.5%的病例中检测到AFB,改良漂白剂法在60.7%的病例中检测到AFB。改良漂白剂法在另外54例常规AFB染色阴性的病例中显示出AFB阳性。改良漂白剂法在常规ZN染色阳性的所有病例中均显示出AFB阳性。
改良漂白剂法比常规ZN染色更敏感、更安全。由于背景清晰,杆菌易于观察,且筛查时间更短。