Shahi Shahriar, Samiei Mohammad, Rahimi Saeed, Nezami Hossein
Department of Endodontics, Dental School, Tabriz University of Medical Sciences, Tabriz, Iran.
Iran Endod J. 2010 Spring;5(2):59-63. Epub 2010 May 20.
The purpose of this in vitro study was to compare the coronal seal of four temporary filling materials, Coltosol, Zonalin, Zamherir, and Intermediate Restorative Material (IRM) by the India ink dye penetration test.
Endodontic access preparations were prepared in 120 extracted intact human premolars. The teeth were randomly divided into six groups including four experimental and two control groups. The access cavities in each group were sealed with Coltosol, Zonalin, Zamherir, and IRM; subsequently thermocycling was applied for 5-55˚C for 150 cycles. The teeth were immersed in 10% India ink for 72 hours to assess leakage. The teeth were then rinsed, dried, and sectioned mesiodistally and evaluated under a stereomicroscope for dye penetration. Data were analyzed using one-way ANOVA and post hoc Tukey tests.
Positive control specimens showed complete dye penetration, while negative controls had no penetration. In the experimental groups, the lowest and highest leakage scores were observed in the Zonalin and Coltosol groups, respectively (P<0.05). There were no statistically significant differences in marginal leakage between Zonalin-Zamherir and Coltosol-IRM groups.
These results suggest that Zonalin and Zamherir have a superior seal and less micro-leakage into the canals compared to the two other materials.
本体外研究的目的是通过印度墨水染料渗透试验比较四种临时充填材料(Coltosol、Zonalin、Zamherir和中间修复材料(IRM))的冠部封闭效果。
在120颗完整拔除的人类前磨牙上制备牙髓通路预备体。将牙齿随机分为六组,包括四个试验组和两个对照组。每组的通路洞用Coltosol、Zonalin、Zamherir和IRM进行封闭;随后在5 - 55˚C下进行150次热循环。将牙齿浸泡在10%的印度墨水中72小时以评估渗漏情况。然后冲洗、干燥牙齿,并沿近远中方向切片,在体视显微镜下评估染料渗透情况。使用单因素方差分析和事后Tukey检验对数据进行分析。
阳性对照标本显示染料完全渗透,而阴性对照没有渗透。在试验组中,Zonalin组和Coltosol组分别观察到最低和最高的渗漏评分(P<0.05)。Zonalin - Zamherir组和Coltosol - IRM组之间的边缘渗漏没有统计学显著差异。
这些结果表明,与其他两种材料相比,Zonalin和Zamherir具有更好的封闭效果,向根管内的微渗漏更少。