Department of Chemistry, Université de Montréal, Montreal, Quebec, Canada.
Talanta. 2012 Nov 15;101:337-45. doi: 10.1016/j.talanta.2012.09.036. Epub 2012 Sep 28.
A new coating material was used for a stir bar sorptive extraction (SBSE) method coupled to a high throughput sample analysis technique. This allowed for a simple procedure for fast determinations of eight steroid hormones (estriol, estradiol, ethynylestradiol, estrone, progesterone, medroxyprogesterone, levonorgestrel, northindrone) in water. Sample pre-treatment was performed using an in-house SBSE method based on a polydimethylsiloxane/phenyltrimethylsiloxane/β-cyclodextrin sol-gel material. The analytes were desorbed by liquid extraction prior to their analysis by laser diode thermal desorption/atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). Several parameters, including ionic strength, volume and time of extraction as well as volume and time of desorption, were investigated to maximize extraction efficiency by SBSE in aqueous solutions. The in-house stir bar showed good reproducibility and could be used for at least 50 extractions without affecting analytical performance. The recoveries of the spiked steroid hormones ranged from 55% to 96% in all water matrices studied (HPLC grade water, tap water and raw wastewater). Only one compound showed poor recovery values (<2% for estriol) in all matrices. The method detection limits (MDLs) in real matrices were within the range of 0.1-0.3 μg L(-1) except for estriol at 48 μg L(-1). The extraction performance of the in-house SBSE for the eight selected hormones was also compared with that of a commercially-available stir bar coated with polydimethylsiloxane (PDMS). This novel stir bar coating could prove to be useful method for the detection and quantification of trace levels of steroid hormones.
一种新型的涂层材料被用于搅拌棒吸附萃取(SBSE)方法与高通量样品分析技术相结合。这使得一种简单的程序可以快速测定水中的八种甾体激素(雌三醇、雌二醇、乙炔雌二醇、雌酮、孕酮、甲羟孕酮、左炔诺孕酮、诺孕酮)。样品预处理采用基于聚二甲基硅氧烷/苯基三甲硅氧烷/β-环糊精溶胶-凝胶材料的自制 SBSE 方法。分析物通过液液萃取解吸,然后通过激光二极管热解吸/大气压化学电离串联质谱(LDTD-APCI-MS/MS)进行分析。研究了几种参数,包括离子强度、萃取体积和时间以及解吸体积和时间,以最大限度地提高水溶液中 SBSE 的萃取效率。自制搅拌棒具有良好的重现性,可至少进行 50 次萃取而不影响分析性能。在所研究的所有水基质(HPLC 级水、自来水和原废水)中,加标甾体激素的回收率为 55%至 96%。只有一种化合物在所有基质中的回收率较差(雌三醇<2%)。实际基质中的方法检测限(MDLs)在 0.1-0.3μg/L 范围内,除雌三醇为 48μg/L 外。自制 SBSE 对这八种选定激素的萃取性能也与市售聚二甲基硅氧烷(PDMS)涂层搅拌棒进行了比较。这种新型搅拌棒涂层可能是检测和定量痕量甾体激素的有用方法。