Suppr超能文献

聚二甲基硅氧烷/金属有机骨架涂层搅拌棒吸附萃取结合高效液相色谱-紫外检测器测定环境水样中的雌激素。

Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to high performance liquid chromatography-ultraviolet detector for the determination of estrogens in environmental water samples.

机构信息

Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, China.

出版信息

J Chromatogr A. 2013 Oct 4;1310:21-30. doi: 10.1016/j.chroma.2013.08.047. Epub 2013 Aug 20.

Abstract

In this work, three kinds of metal-organic frameworks (MOFs), MOF-5, MOF-199 and IRMOF-3, were introduced in stir bar sorptive extraction (SBSE) and novel polydimethylsiloxane (PDMS)/MOFs (including PDMS/MOF-5, PDMS/MOF-199 and PDMS/IRMOF-3) coated stir bars were prepared by sol-gel technique. These PDMS/MOFs coatings were characterized and critically compared for the extraction of seven target estrogens (17-β-estradiol, dienestrol, diethylstilbestrol, estrone, 4-t-octylphenol, bisphenol-A and 17α-ethynylestradiol) by SBSE, and the results showed that PDMS/IRMOF-3 exhibited highest extraction efficiency. Based on the above facts, a novel method of PDMS/IRMOF-3 coating SBSE-high performance liquid chromatography ultraviolet (HPLC-UV) detection was developed for the determination of seven target estrogens in environmental waters. Several parameters affecting extraction of seven target estrogens by SBSE (PDMS/IRMOF-3) including extraction time, stirring rate, pH, ionic strength, desorption solvent and desorption time were investigated. Under the optimal experimental conditions, the limits of detection (LODs, S/N=3) were found to be in the range of 0.15-0.35 μg/L. The linear range was 2-2,500 μg/L for 17α-ethynylestradiol and 1-2,500 μg/L for other estrogens. The relative standard deviations (RSDs) were in the range of 3.7-9.9% (n=8, c=20 μg/L) and the enrichment factors were from 30.3 to 55.6-fold (theoretical enrichment factor was 100-fold). The proposed method was successfully applied to the analysis of estrogens in environmental water samples, and quantitative recoveries were obtained for the spiking experiments.

摘要

在这项工作中,引入了三种金属有机骨架(MOFs),即 MOF-5、MOF-199 和 IRMOF-3,用于搅拌棒吸附萃取(SBSE)中,并通过溶胶-凝胶技术制备了新型聚二甲基硅氧烷(PDMS)/MOFs(包括 PDMS/MOF-5、PDMS/MOF-199 和 PDMS/IRMOF-3)涂层搅拌棒。对这些 PDMS/MOFs 涂层进行了表征,并对其进行了严格比较,以用于通过 SBSE 萃取七种目标雌激素(17-β-雌二醇、双烯雌酚、己烯雌酚、雌酮、4-t-辛基苯酚、双酚 A 和 17α-乙炔雌二醇),结果表明 PDMS/IRMOF-3 具有最高的萃取效率。基于上述事实,建立了一种 PDMS/IRMOF-3 涂层搅拌棒吸附萃取-高效液相色谱紫外检测(SBSE-HPLC-UV)新方法,用于测定环境水中的七种目标雌激素。考察了影响 SBSE(PDMS/IRMOF-3)萃取七种目标雌激素的几个参数,包括萃取时间、搅拌速率、pH 值、离子强度、洗脱溶剂和洗脱时间。在最佳实验条件下,发现七种目标雌激素的检测限(LODs,S/N=3)在 0.15-0.35 μg/L 范围内。17α-乙炔雌二醇的线性范围为 2-2500 μg/L,其他雌激素的线性范围为 1-2500 μg/L。相对标准偏差(RSDs)在 3.7-9.9%(n=8,c=20 μg/L)范围内,富集因子为 30.3-55.6 倍(理论富集因子为 100 倍)。该方法成功应用于环境水样中雌激素的分析,并对加标实验进行了定量回收。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验