Avula Bharathi, Wang Yan-Hong, Khan Ikhlas A
The University of Mississippi, National Center for Natural Products Research, Research Institute of Pharmaceutical Sciences, University, MS 38677, USA.
J AOAC Int. 2012 Sep-Oct;95(5):1398-405. doi: 10.5740/jaoacint.12-074.
Ultra-performance liquid chromatography (UPLC) with UV detection was used for the quantification of alkaloids from roots of Hydrastis canadensis L. (goldenseal) and dietary supplements claiming to contain goldenseal. The analysis was performed on a Waters Acquity UPLC system with an Acquity UPLC BEH Shield RP18 column using gradient elution with ammonium formate and acetonitrile containing formic acid. The chromatographic run time was less than 6 min. The detection wavelength used for beta-hydrastine and canadine was 290 nm; for hydrastinine, coptisine, jatrorrhizine, palmatine, and berberine, it was 344 nm. A total of five different extraction solvents, including 100% methanol, 90% methanol, 90% methanol + 1% acetic acid, 90% acetonitrile + 0.1% phosphoric acid, and 100% acetonitrile, were tested for recovery of the major compounds. The samples extracted with the 90% methanol + 1% acetic acid displayed the best recovery (>97%). The analytical method was validated for linearity, repeatability, LOD, and LOQ. The RSDs for intraday and interday experiments were less than 3.5%, and the recovery was 98-103%. UPLC/MS with a quadrupole mass analyzer and electrospray ionization source was used to confirm the identity of seven alkaloids. The analytical method was successfully applied to confirm the identification of seven alkaloids from the roots of H. canadensis, dietary supplements that claimed to contain goldenseal, and possible adulterant species.
采用带紫外检测的超高效液相色谱法(UPLC)对白毛茛(Hydrastis canadensis L.)根中的生物碱以及声称含有白毛茛的膳食补充剂进行定量分析。分析在Waters Acquity UPLC系统上进行,使用Acquity UPLC BEH Shield RP18色谱柱,采用甲酸铵和含甲酸的乙腈进行梯度洗脱。色谱运行时间少于6分钟。用于β-白毛茛碱和加拿大黄连碱的检测波长为290nm;用于白毛茛宁、黄连碱、药根碱、巴马汀和小檗碱的检测波长为344nm。共测试了五种不同的提取溶剂,包括100%甲醇、90%甲醇、90%甲醇 + 1%乙酸、90%乙腈 + 0.1%磷酸和100%乙腈,以考察主要化合物的回收率。用90%甲醇 + 1%乙酸提取的样品回收率最佳(>97%)。该分析方法进行了线性、重复性、检测限和定量限的验证。日内和日间实验的相对标准偏差小于3.5%,回收率为98 - 103%。采用配备四极杆质量分析仪和电喷雾电离源的UPLC/MS确认了七种生物碱的身份。该分析方法成功应用于确认从白毛茛根、声称含有白毛茛的膳食补充剂以及可能的掺假物种中七种生物碱的鉴定。