Suppr超能文献

Swan-Ganz导管致肺动脉破裂:经导管栓塞术成功早期处理

Swan-Ganz catheter-induced rupture of the pulmonary artery: successful early management by transcatheter embolization.

作者信息

Jondeau G, Lacombe P, Rocha P, Rigaud M, Hardy A, Bourdarias J P

机构信息

Department of Cardiology, Hopital Ambroise Paré, Boulogne, France.

出版信息

Cathet Cardiovasc Diagn. 1990 Mar;19(3):202-4. doi: 10.1002/ccd.1810190312.

Abstract

An 84-year-old patient with severe aortic valve stenosis suffered Swan-Ganz catheter-induced massive pulmonary hemorrhage. Immediate therapeutic embolism of the segmental artery by using a liquid, tissue-adhesive, occlusive agent (isobutyl-2-cyanoacrylate) controlled bleeding.

摘要

一名84岁重度主动脉瓣狭窄患者发生了 Swan-Ganz 导管所致的大量肺出血。立即使用液体组织黏合剂闭塞剂(异丁基-2-氰基丙烯酸酯)对节段动脉进行治疗性栓塞,从而控制了出血。

相似文献

3
[Management of a catheter-induced rupture of a pulmonary artery].[导管所致肺动脉破裂的处理]
Dtsch Med Wochenschr. 2010 Oct;135(39):1914-7. doi: 10.1055/s-0030-1263338. Epub 2010 Sep 21.
6
[Pulmonary artery rupture with Swan-Ganz catheter during cardiac surgery: management and decision-making].
Ann Chir. 2006 Oct;131(8):426-30. doi: 10.1016/j.anchir.2005.12.020. Epub 2006 Jan 23.