Institute for Biological and Medical Imaging, Helmholtz Zentrum München, Ingolstädter Landstrasse 1, 85764 Neuherberg, Germany.
J Biomed Opt. 2012 Dec;17(12):126011. doi: 10.1117/1.JBO.17.12.126011.
We examine the improvement in imaging performance, such as axial resolution and signal localization, when employing limited-projection-angle fluorescence molecular tomography (FMT) together with x-ray computed tomography (XCT) measurements versus stand-alone FMT. For this purpose, we employed living mice, bearing a spontaneous lung tumor model, and imaged them with FMT and XCT under identical geometrical conditions using fluorescent probes for cancer targeting. The XCT data was employed, herein, as structural prior information to guide the FMT reconstruction. Gold standard images were provided by fluorescence images of mouse cryoslices, providing the ground truth in fluorescence bio-distribution. Upon comparison of FMT images versus images reconstructed using hybrid FMT and XCT data, we demonstrate marked improvements in image accuracy. This work relates to currently disseminated FMT systems, using limited projection scans, and can be employed to enhance their performance.
我们研究了在采用有限角度荧光分子断层扫描(FMT)与 X 射线计算机断层扫描(XCT)联合测量时,成像性能的改善,如轴向分辨率和信号定位,与单独的 FMT 相比。为此,我们使用携带自发性肺癌模型的活小鼠,在相同的几何条件下使用荧光探针进行癌症靶向,对其进行 FMT 和 XCT 成像。在此,将 XCT 数据用作 FMT 重建的结构先验信息。荧光图像的小鼠冷冻切片提供了荧光生物分布的真实信息,为荧光标准图像提供了金标准。通过将 FMT 图像与使用混合 FMT 和 XCT 数据重建的图像进行比较,我们证明了图像准确性的显著提高。这项工作与目前传播的有限投影扫描 FMT 系统有关,并可用于提高其性能。