Suppr超能文献

超高效液相色谱法同时测定化妆品中9种邻苯二甲酸酯和双酚A

[Simultaneous determination of nine phthalate esters and bisphenol A in cosmetics by ultra-high performance liquid chromatography].

作者信息

Liu Yuhong, Wang Ping, Li Jie

机构信息

Beijing Center for Disease Prevention and Control, Beijing 100013, China.

出版信息

Wei Sheng Yan Jiu. 2012 Sep;41(5):846-9.

Abstract

OBJECTIVE

An ultra-performance liquid chromatography method has been established for the simultaneous determination of 9 phthalate esters and bisphenol A in cosmetics.

METHODS

The samples were extracted by methanol and determined by ultra-high performance liquid chromatography with PDA detector. The separation of 9 phthalate esters and bisphenol A was carried out by an Phenyl column (50 mm x 2.1 mm id, 1.7 microm) column and quantification was based on detection wavelength at 275 nm.

RESULTS

The linear ranges of the calibration curves for 9 phthalate esters and bisphenol A were 10-300 microg/ml and 5-150 micro g/ml, respectively. The correlation coefficients of the standard curves were all higher than 0.9996. The limits of detection (LODs) for phthalate esters were 0.4-0.81 microg/ml and bisphenol A was 0.2 microg/ml. The average recoveries at the concentrations studied were in the range from 91.9% to 105.4%. Relative standard deviations were all less than 5.23%.

CONCLUSION

The method is simple, fast and effective, and could meet the needs for routine analysis of the 9 phthalate esters and bisphenol A in cosmetics.

摘要

目的

建立了一种同时测定化妆品中9种邻苯二甲酸酯和双酚A的超高效液相色谱法。

方法

样品用甲醇提取,采用配有二极管阵列检测器的超高效液相色谱仪进行测定。9种邻苯二甲酸酯和双酚A的分离采用苯基柱(50 mm×2.1 mm内径,1.7μm),定量检测波长为275 nm。

结果

9种邻苯二甲酸酯和双酚A校准曲线的线性范围分别为10~300μg/ml和5~150μg/ml。标准曲线的相关系数均高于0.9996。邻苯二甲酸酯的检出限为0.4~0.81μg/ml,双酚A的检出限为0.2μg/ml。在所研究的浓度下,平均回收率在91.9%~105.4%范围内。相对标准偏差均小于5.23%。

结论

该方法简便、快速、有效,可满足化妆品中9种邻苯二甲酸酯和双酚A的常规分析需求。