不同品牌种植体与基台的精准组合。

Accuracy combining different brands of implants and abutments.

机构信息

Department of Buccofacial Prosthetics, Faculty of Medicine and Dentistry, Universitat de València, Spain.

出版信息

Med Oral Patol Oral Cir Bucal. 2013 Mar 1;18(2):e332-6. doi: 10.4317/medoral.18137.

Abstract

OBJECTIVE

To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination.

STUDY DESIGN

Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S.A. (Barcelona, Spain), 3i Biomet (Palm Beach, U.S.A.), BTI (Alava, Spain) and Nobel Biocare (Göteborg, Sweden), with standard 4.1 mm heads and external hexagons, and their respective machined prosthetic abutments. The implant-to-abutment fit/misfit was evaluated at four points (vestibular, lingual/palatine, mesial and distal) between implants and abutments of the same brand and different brands, with or without mechanical torque, using SEM micrographs at 5000X. Image analysis was performed using NIS-Elements software (Nikon Instruments Europe B.V.).

RESULTS

Before applying torque, vertical misfit (microgaps) of the different combinations tested varied between 1.6 and 5.4 microns and after applying torque, between 0.9 and 5.9 microns, an overall average of 3.46 ± 2.96 microns. For manual assembly without the use of mechanical torque, the best results were obtained with the combination of the 3i implant and the BTI abutment. The Nobel implant and Nobel abutment, 3i-3i and BTI-BTI and the combination of 3i implant with BTI or Nobel abutment provided the best vertical fit when mechanical torque was applied.

CONCLUSIONS

The vertical fits obtained were within the limits considered clinically acceptable. The application of mechanical torque improved outcomes. There is compatibility between implants and abutments of different brand and so their combination is a clinical possibility.

摘要

目的

评估不同品牌的牙种植体和修复基台之间存在或不存在机械扭矩时的垂直不匹配情况,并研究它们可能的组合。

研究设计

本研究使用了五种不同品牌的种植体:Biofit(意大利卡斯特马焦雷)、Bioner S.A.(西班牙巴塞罗那)、3i Biomet(美国棕榈滩)、BTI(西班牙阿拉瓦)和 Nobel Biocare(瑞典哥德堡),均带有标准的 4.1 毫米头部和外六角,以及各自加工的修复基台。在四个点(颊侧、舌侧/腭侧、近中和远中)评估同一品牌和不同品牌的种植体和基台之间的种植体-基台适配/不匹配情况,评估时种植体和基台存在或不存在机械扭矩,使用 SEM 显微照片在 5000X 下进行。使用 NIS-Elements 软件(Nikon Instruments Europe B.V.)进行图像分析。

结果

在施加扭矩之前,不同组合的垂直不匹配(微间隙)测试值在 1.6 到 5.4 微米之间,施加扭矩后,在 0.9 到 5.9 微米之间,平均为 3.46±2.96 微米。对于不使用机械扭矩的手动组装,3i 种植体和 BTI 基台的组合效果最好。当施加机械扭矩时,Nobel 种植体和 Nobel 基台、3i-3i 和 BTI-BTI 以及 3i 种植体与 BTI 或 Nobel 基台的组合提供了最佳的垂直适配。

结论

所获得的垂直适配在临床可接受的范围内。机械扭矩的应用改善了结果。不同品牌的种植体和基台之间具有兼容性,因此它们的组合具有临床可行性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5f16/3613888/7b2a524043ff/medoral-18-e332-g001.jpg