Ward James P, Kim L T Suezie, Rettig Michael E
Dept. of Orthopaedic Surgery, NYU Hospital for Joint Diseases, 301 East 17th Street, New York, NY 10003, USA.
Bull NYU Hosp Jt Dis. 2012;70(4):273-5.
Distal radius fractures are among the most commonly encountered fractures in the extremities. Volar plating of distal radius fracture has gained popularity in recent years with the introduction of the locked plating system. Complications of volar plating include extensor and flexor tendon rupture. Here we present a case report of an extensor indicis proprius and extensor digitorum communis to index finger tendon rupture after open reduction and internal fixation of distal radius fracture with locked plate.
桡骨远端骨折是四肢最常见的骨折之一。近年来,随着锁定钢板系统的引入,桡骨远端骨折的掌侧钢板固定越来越普遍。掌侧钢板固定的并发症包括伸肌腱和屈肌腱断裂。在此,我们报告一例在使用锁定钢板对桡骨远端骨折进行切开复位内固定后,示指固有伸肌和示指指总伸肌腱断裂的病例。