Classen A, Miersch W D, Hesse A
Experimentelle Urologie, Urologische Universitätsklinik Bonn, FRG.
J Clin Chem Clin Biochem. 1990 Feb;28(2):91-4. doi: 10.1515/cclm.1990.28.2.91.
An ion-chromatographic system was used for the simultaneous determination of urinary phosphate and sulphate. This method was compared with conventional methods (colorimetric, turbidimetric) with regard to practicability and reliability. All methods showed good precision and accuracy. The comparative analysis of phosphate in 80 samples revealed that both methods lead to identical results. However, in case of sulphate a significant difference of about 8% was found between the two methods. Overestimation of the analyte concentration by the turbidimetric method might be responsible for this difference. From the point of view of economy, routine analysis of urinary phosphate and sulphate by ion-chromatography is acceptable only if automated systems are used.
采用离子色谱系统同时测定尿中的磷酸盐和硫酸盐。就实用性和可靠性而言,将该方法与传统方法(比色法、比浊法)进行了比较。所有方法均显示出良好的精密度和准确度。对80份样品中的磷酸盐进行的对比分析表明,两种方法得出的结果相同。然而,在硫酸盐测定中,两种方法之间发现了约8%的显著差异。比浊法对分析物浓度的高估可能是造成这种差异的原因。从经济性角度来看,只有使用自动化系统时,通过离子色谱法对尿中的磷酸盐和硫酸盐进行常规分析才是可行的。