Faculty of Science and Engineering, School of Chemistry and the Environment, Division of Chemistry and Environmental Science, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, Lancs, UK.
Analyst. 2013 Feb 21;138(4):1053-9. doi: 10.1039/c2an36450f.
We present the electroanalytical sensing of atropine using disposable and economic screen printed graphite sensors. The electroanalytical determination of atropine is found to be possible over the concentration range of 5 μM to 50 μM with a detection limit of 3.9 μM (based on 3-sigma) found to be possible. We demonstrate proof-of-concept that this approach provides a rapid and inexpensive sensing strategy for determining the molecule of murder atropine in diet Coca-Cola samples.