A method for indirect fluorescent antibody (IFA) assay for soluble antigen has been developed using latex particles (latex) as a carrier for soluble antigen. Two types of latex having grain sizes of 1.0 and 6.0 μm were used for IFA assay and were evaluated in this study. Bovine IgG and rabbit anti-bovine IgG antibody were used as soluble antigen and as primary antibody, respectively. Bovine IgG-sensitized latex on slide glass was not washed off after immersion for 45 min. IFA using latex appears to have high specificity, as no reactions between fluorescein isothiocyanate (FITC)-conjugated antibody and protein-sensitized latex were observed, and the latex did not show auto-fluorescence or non-specific reactions. Latex with a grain size of 6.0 μm was appropriate as a carrier of soluble antigen, as the amount of soluble antigen necessary for sensitization was approximately one-eighth that necessary for the small-diameter latex (1.0 μm), and large-diameter latex is easier to distinguish under the fluorescence microscope. IFA assay using soluble antigen-sensitized latex is suitable for more widespread use in the future.
已开发出一种以乳胶颗粒(乳胶)作为可溶性抗原载体的间接荧光抗体(IFA)检测可溶性抗原的方法。本研究使用了粒径分别为1.0和6.0μm的两种类型乳胶进行IFA检测并对其进行评估。牛IgG和兔抗牛IgG抗体分别用作可溶性抗原和一抗。载玻片上的牛IgG致敏乳胶在浸泡45分钟后未被冲洗掉。使用乳胶的IFA似乎具有高特异性,因为未观察到异硫氰酸荧光素(FITC)偶联抗体与蛋白质致敏乳胶之间的反应,并且乳胶未显示自发荧光或非特异性反应。粒径为6.0μm的乳胶适合作为可溶性抗原的载体,因为致敏所需的可溶性抗原量约为小直径乳胶(1.0μm)所需量的八分之一,并且大直径乳胶在荧光显微镜下更容易区分。使用可溶性抗原致敏乳胶的IFA检测在未来更适合广泛应用。