使用平板扫描仪对 EBT 和 EBT2 Gafchromic 胶片剂量计进行数字化的扫描参数的定量研究。

Quantitative investigation of the effects of the scanning parameters in the digitization of EBT and EBT2 Gafchromic film dosimetry with flatbed scanners.

机构信息

Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA.

出版信息

J Xray Sci Technol. 2012;20(4):385-93. doi: 10.3233/XST-2012-00346.

Abstract

With increasing popularity and complexity of intensity-modulated radiation therapy (IMRT) delivery modalities including regular and arc therapies, there is a growing challenge for validating the accuracy of dose distributions. Gafchromic films have superior characteristics for dose verification over other conventional dosimeters. In order to optimize the use of Gafchromic films in clinical IMRT quality assurance procedures, the scanning parameters of EBT and EBT2 films with a flatbed scanner were investigated. The effects of several parameters including scanning position, orientation, uniformity, film sensitivity and optical density (OD) growth after irradiation were quantified. The profiles of the EBT and EBT2 films had a noise level of 0.6% and 0.7%, respectively. Considerable orientation dependence was observed and the scanner value difference between landscape and portrait modes were about 12% and 10% for EBT and EBT2 films, respectively. The highest response sensitivity was observed using digitized red color images of the EBT2 film scanned with landscape mode. The total system non-uniformity composed of contributions from the film and the scanner was less than 1.7%. OD variations showed that EBT gray scale grew slower, however, reached higher growth values of 15% when compared with EBT2 gray scale which grew 12% after a long time (480 hours) post-irradiation. The EBT film using the red color channel showed the minimal growth where OD increased up to 3% within 3 days after irradiation, and took one week to stabilize.

摘要

随着强度调制放射治疗(IMRT)技术的普及和复杂性不断增加,包括常规和弧形治疗,验证剂量分布的准确性面临着越来越大的挑战。Gafchromic 胶片在剂量验证方面具有优于其他传统剂量计的特性。为了优化 Gafchromic 胶片在临床 IMRT 质量保证程序中的使用,研究了平板扫描仪对 EBT 和 EBT2 胶片的扫描参数。量化了包括扫描位置、方向、均匀性、胶片灵敏度和辐照后光密度(OD)增长等几个参数的影响。EBT 和 EBT2 胶片的轮廓噪声水平分别为 0.6%和 0.7%。观察到相当大的方向依赖性,EBT 和 EBT2 胶片的扫描仪值在景观和肖像模式之间的差值分别约为 12%和 10%。使用扫描时采用景观模式的 EBT2 胶片的数字化红色彩色图像,观察到最高的响应灵敏度。由胶片和扫描仪贡献的总系统不均匀性小于 1.7%。OD 变化表明 EBT 灰度增长较慢,但在长时间(480 小时)辐照后,EBT 灰度增长 15%,而 EBT2 灰度增长 12%。EBT 胶片使用红色彩色通道显示出最小的增长,辐照后 3 天内 OD 增加了 3%,并在一周内稳定下来。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验