Suppr超能文献

定制铝夹板与传统铝夹板治疗远节指骨损伤的疗效比较

Comparison effectiveness of custom-made versus conventional aluminum splint for distal phalange injury.

作者信息

Chotigavanichaya Chatupon, Limthongthang Roongsak, Pimonsiripol Thanawat, Harnroongroj Thossart, Songcharoen Panupan

机构信息

Department of Orthopaedic Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.

出版信息

J Med Assoc Thai. 2012 Sep;95 Suppl 9:S70-4.

Abstract

BACKGROUND

Finger splint is a simple and common method for finger immobilization. The flexible aluminum foam-padded splint is a convenient off-the-shelf inexpensive splint. But there're some studies favor expensively custom-made thermoplastic splint due to its less likely result in treatment failure. Therefore the authors have modified the conventional aluminum finger splint in the foam-padded part to improve the fitting and compliance of the patients.

OBJECTIVE

To compare the fitting of custom-made aluminum finger splint with conventional aluminum finger splint.

MATERIAL AND METHOD

Sixty volunteers were randomized to apply 30 conventional or custom-made aluminum splints on 4th digit in non dominated hand for one week. The fitting of each splint was measured by displacement of the splint between initial placement and one week later. Patient satisfaction and pain was measured by visual analog score (VAS).

RESULTS

The slip and deviation in custom-made group were less than the conventional group significantly (mean of slip 0.86 mm vs. 2.23 mm, p < 0.001, mean of deviation 1.1 degrees vs. 2.23 degrees,p < 0.001) but the longitudinal migration was not significantly difference between both groups (mean 1.6 mm in custom-made group vs. 1.46 mm in conventional group, p = 0.67). The patient satisfaction demonstrated no significant difference between both groups (mean VAS 7.76 in custom-made group vs. 7.3 in conventional group, p = 0.31). Two patients terminated from the present study before one week in custom-made group and one patient in the conventional group (6.67% vs. 3.33%, p = 0.554).

CONCLUSION

The custom-made aluminum finger splint can improve the fitting to the finger pulp. However, patient satisfaction and compliance are not significantly different between both groups.

摘要

背景

手指夹板是一种简单且常用的手指固定方法。柔性泡沫铝垫夹板是一种方便的现成廉价夹板。但有一些研究支持使用昂贵的定制热塑性夹板,因为其导致治疗失败的可能性较小。因此,作者对传统铝制手指夹板的泡沫填充部分进行了改良,以提高患者的贴合度和依从性。

目的

比较定制铝制手指夹板与传统铝制手指夹板的贴合度。

材料与方法

60名志愿者被随机分为两组,分别在非优势手的无名指上使用30个传统或定制铝制夹板,持续一周。通过夹板在初始放置和一周后的位移来测量每个夹板的贴合度。通过视觉模拟评分(VAS)测量患者满意度和疼痛程度。

结果

定制组的滑动和偏差明显小于传统组(滑动平均值0.86毫米对2.23毫米,p<0.001;偏差平均值1.1度对2.23度,p<0.001),但两组之间的纵向移动没有显著差异(定制组平均值1.6毫米,传统组平均值1.46毫米,p = 0.67)。两组患者满意度无显著差异(定制组平均VAS为7.76,传统组为7.3,p = 0.31)。定制组有2名患者在一周前退出本研究,传统组有1名患者退出(6.67%对3.33%,p = 0.554)。

结论

定制铝制手指夹板可提高对手指 pulp 的贴合度。然而,两组之间患者满意度和依从性无显著差异。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验