Abstract

PURPOSE

Orbital osteotomy risks injury to the eyeball and orbit soft tissues. Used extensively in oral and maxillofacial surgery, piezoelectric technology offers a greater margin of safety than traditional bone cutting instruments. The authors describe the novel use of this system in a variety of orbital surgeries.

METHODS

This interventional case series was performed in accordance with institutional review board regulations. The medical records of all patients who had undergone orbital surgery using the piezoelectric blade at 3 institutions were reviewed. Indication for surgery, gender, age, duration of follow up, intraoperative complications, surgical result, and postoperative course was recorded.

RESULTS

Sixteen patients underwent surgery on 18 orbits using the piezoelectric system between August 2011 and June 2012. Surgeries performed included orbital decompression (8), lateral orbitotomy (5), cranio-orbitotomy (4), and external dacryocystorhinostomy (1). Eight were female and 8 were male patients. Mean age was 55 years old (standard deviation 15 years). Mean follow up was 82 days. The osteotomy created by the blade was narrow and smooth in every case. The surgeons uniformly appreciated the precision and safety of the instrument compared with traditional electric saw blades. There were no soft tissue lacerations or intraoperative complications and reconstructions were uniformly uneventful. Postoperative healing was rapid with no unexpected inflammation, and no palpable bony defects were appreciated in the reconstructed cases.

CONCLUSIONS

Because it does not cut soft tissue and cuts a narrow trough, the self-irrigating piezoelectric saw blade appears safer and more precise than traditional electric saw blades in and around the orbit.

摘要

目的

眼眶切开术有损伤眼球和眼眶软组织的风险。在口腔颌面外科中广泛应用的压电技术比传统的骨切割器械具有更大的安全裕度。作者描述了该系统在各种眼眶手术中的新应用。

方法

本介入性病例系列研究符合机构审查委员会的规定。对 3 家机构使用压电刀片进行眼眶手术的所有患者的病历进行了回顾。记录手术适应证、性别、年龄、随访时间、术中并发症、手术结果和术后过程。

结果

2011 年 8 月至 2012 年 6 月期间,16 例患者的 18 只眼眶采用压电系统进行了手术。手术包括眼眶减压术(8 例)、外侧眶切开术(5 例)、颅面眶切开术(4 例)和外鼻泪囊吻合术(1 例)。8 例为女性,8 例为男性。平均年龄为 55 岁(标准差 15 岁)。平均随访时间为 82 天。刀片所形成的骨切缘在每例中均狭窄而光滑。与传统的电锯相比,外科医生一致认为该器械具有精确性和安全性。没有发生软组织撕裂或术中并发症,重建均顺利进行。术后愈合迅速,无意外炎症,重建病例中未触及明显的骨缺损。

结论

由于它不会切割软组织,并且只切割狭窄的槽,因此在眼眶内外,自灌洗压电锯片似乎比传统的电锯更安全、更精确。