To study coagulation of live liver donors with standard coagulation tests (SCT) and rotational thromboelastometry (ROTEM) and investigate their relationship.
A descriptive prospective study involving 50 right hepatotomy donors with epidural catheters. ROTEM (EXTEM, INTEM, and FIBTEM represent extrinsic and intrinsic pathways of coagulation and fibrinogen activity, respectively) was measured perioperatively and on days 1, 3, 5, 10, and 30. SCTs include prothrombin time (PT), international normalized ratio (INR) of PT, activated partial thromboplastin time (aPPT), fibrinogen, and platelets.
PT and INR reflect hypocoagulability reaching maximum on day one (16.9 ± 2.5 s, 1.4 ± 0.2, p < 0.05 compared with baseline). ROTEM was in normal ranges till day 30 with no hypercoagulability. Fibrinogen showed no correlation with maximum clot firmness (MCF) of FIBTEM (r = 0.35, p > 0.05). CFT of EXTEM was not in significant correlation with PT and INR (r = 0.16, 0.19, p > 0.05), respectively. Significant correlation between platelets and both MCF (EXTEM; r = 0.59, p = 0.004) and MCF (INTEM; r = 0.48, p = 0.027).
ROTEM disagreed with SCTs and did not show the temporary hypocoagulability suggested by SCTs. Both ROTEM and SCTs showed no signs of hypercoagulability. Future studies involving ROTEM could help develop new guidelines for coagulation monitoring.
通过标准凝血测试(SCT)和旋转血栓弹性测定法(ROTEM)研究活体肝移植供体的凝血情况,并探讨两者之间的关系。
这是一项描述性前瞻性研究,共纳入 50 例行右半肝切除术的硬膜外导管供体。ROTEM(EXTEM、INTEM 和 FIBTEM 分别代表凝血和纤维蛋白原活性的外源性和内源性途径)在围手术期以及术后第 1、3、5、10 和 30 天进行测量。SCT 包括凝血酶原时间(PT)、PT 的国际标准化比值(INR)、活化部分凝血活酶时间(aPPT)、纤维蛋白原和血小板。
PT 和 INR 反映低凝状态,在第 1 天达到最大值(16.9 ± 2.5 s,1.4 ± 0.2,与基线相比,p < 0.05)。ROTEM 在第 30 天仍处于正常范围,无高凝状态。纤维蛋白原与 FIBTEM 的最大凝块硬度(MCF)无相关性(r = 0.35,p > 0.05)。EXTEM 的 CFT 与 PT 和 INR 无显著相关性(r = 0.16,0.19,p > 0.05)。血小板与 EXTEM 的 MCF(r = 0.59,p = 0.004)和 INTEM 的 MCF(r = 0.48,p = 0.027)呈显著相关。
ROTEM 与 SCT 不一致,且未显示 SCT 提示的短暂性低凝状态。ROTEM 和 SCT 均无高凝状态迹象。涉及 ROTEM 的未来研究可能有助于制定新的凝血监测指南。