Young A W, Redmond M D, Hemler D E, Belandres P V
Brooke Army Medical Center, San Antonio, TX.
Arch Phys Med Rehabil. 1990 May;71(6):399-402.
The radial motor nerve fibers were studied in 30 subjects using a technique of surface stimulation in the axilla and the antecubital fossa. Surface recording over the extensor digitorum communis 8cm from the distal stimulation site was done. Mean distal latency was 2.6msec (SD = 0.44), amplitude 11.24mV (SD = 3.5), and conduction velocity 68m/sec (SD = 7.0). Side-to-side comparison using the t-test demonstrated no significant differences. Five subjects were tested 75 more times on two successive days and showed a variation in latency of 0.2msec or less in 74 of 75 trials. Amplitude was consistent during each day's trial, but it varied slightly from one day to the next. Three case reports show the usefulness of the procedure.
采用腋窝和肘前窝表面刺激技术,对30名受试者的桡神经运动纤维进行了研究。在距远端刺激部位8厘米处的指总伸肌上进行表面记录。平均远端潜伏期为2.6毫秒(标准差=0.44),波幅为11.24毫伏(标准差=3.5),传导速度为68米/秒(标准差=7.0)。使用t检验进行双侧比较,结果显示无显著差异。5名受试者在连续两天内又接受了75次测试,在75次试验中的74次中,潜伏期变化为0.2毫秒或更小。在每天的试验中波幅是一致的,但从一天到下一天略有变化。三个病例报告显示了该方法的实用性。