Department of Environmental Health Sciences, University of Michigan, Ann Arbor, MI 48109-2029, USA.
J Chromatogr A. 2013 Mar 1;1279:76-85. doi: 10.1016/j.chroma.2013.01.009. Epub 2013 Jan 9.
This article describes the development and characterization of a partially selective preconcentrator/focuser (PCF) module for a field-portable micro-scale gas chromatograph (μGC) designed to rapidly determine trace levels of two vapor-phase markers of the explosive trinitrotoluene (TNT): 2,3-dimethyl-2,3-dinitrobutane (DMNB) and 2,4-dinitrotoluene (2,4-DNT). The PCF module has three primary components. The first is a high-volume sampler, comprising a resistively-heated 6-cm long stainless steel tube packed with tandem beds of the graphitized carbons Carbopack B (C-B, 30 mg) and Carbopack Y (C-Y, 15 mg), which traps the markers but permits more volatile interferences to pass through largely unretained. The second component is a microfocuser (μF), comprising a 4.2×9.8 mm Si chip containing a deep-reactive-ion-etched (DRIE) cavity packed with 2mg of C-B, a Pyrex cap, integrated heaters, and etched fluidic channels. The third component is a commercial polymer-membrane filter used as a pre-trap to remove particles and adsorbed low volatility interferences. Markers captured in the sampler are thermally desorbed and transferred to the μF, and then thermally desorbed/injected from the μF into a downstream separation (micro)column and detected. Scrubbed ambient air is used as carrier gas. The adsorbent capacities, baseline temperatures, sampling and desorption flow rates, and heating profiles were optimized for each PCF module component while minimizing the analysis time. An overall transfer efficiency of 86% was achieved at marker concentrations of ~0.2-2.6 ppb. In the final configuration the PCF module requires just 60s to collect a 1-L sample (3 L/min), focus (40 mL/min), and inject the markers (3 mL/min), producing half-maximum injection peak widths of ~2 and 5 s, and preconcentration factors of 4500 and 1800, for DMNB and 2,4-DNT, respectively.
本文描述了一种部分选择性预浓缩器/聚焦器 (PCF) 模块的开发和特性,该模块用于设计用于快速测定痕量爆炸物三硝基甲苯 (TNT) 的两种气相标记物:2,3-二甲基-2,3-二硝基丁烷 (DMNB) 和 2,4-二硝基甲苯 (2,4-DNT) 的便携式微尺度气相色谱仪 (μGC)。PCF 模块有三个主要组成部分。第一部分是大容量采样器,由一个加热到电阻的 6 厘米长的不锈钢管组成,管内填充串联的石墨化碳 Carbopack B(C-B,30mg)和 Carbopack Y(C-Y,15mg)床,这些床可以捕获标记物,但允许更多挥发性干扰物通过而基本不保留。第二部分是微聚焦器(μF),由一个 4.2×9.8 毫米的 Si 芯片组成,该芯片包含一个深反应离子刻蚀(DRIE)腔,腔内填充 2mg 的 C-B、一个 Pyrex 盖、集成加热器和刻蚀的流体通道。第三部分是用作预捕集器的商用聚合物膜过滤器,用于去除颗粒和吸附的低挥发性干扰物。在采样器中捕获的标记物被热解吸并转移到 μF,然后从 μF 热解吸/注入到下游分离(微)柱中并检测。净化的环境空气用作载气。在最小化分析时间的同时,优化了每个 PCF 模块组件的吸附容量、基线温度、采样和解吸流速以及加热曲线。在标记物浓度约为 0.2-2.6ppb 时,实现了 86%的整体转移效率。在最终配置中,PCF 模块只需 60 秒即可收集 1L 样品(3L/min)、聚焦(40mL/min)和注入标记物(3mL/min),产生的 DMNB 和 2,4-DNT 的最大注入峰宽分别约为 2 和 5s,预浓缩因子分别为 4500 和 1800。