Suppr超能文献

中重度膝关节骨关节炎患者膝关节角度和力矩步态波形主成分和离散参数的可靠性。

Reliability of principal components and discrete parameters of knee angle and moment gait waveforms in individuals with moderate knee osteoarthritis.

机构信息

Centre for Interdisciplinary Research in Rehabilitation, Constance Lethbridge Rehabilitation, Montreal, QC, Canada.

出版信息

Gait Posture. 2013 Jul;38(3):421-7. doi: 10.1016/j.gaitpost.2013.01.001. Epub 2013 Jan 26.

Abstract

Gait measures are used to evaluate change in patients with knee osteoarthritis (OA), but reliability has not been fully established in this population. This study examined test-retest reliability of knee angle and moment gait waveform characteristics captured using discrete parameters and principal component analysis (PCA) in individuals with moderate knee OA. Participants (n=20) underwent three-dimensional gait analysis on two occasions. Motion and force data were captured using two camera banks, infrared light emitting diodes and force plate during self-selected walking. Knee angle and moment waveforms were calculated and analyzed using discrete parameters and by identifying waveform characteristics using PCA. Intraclass correlation coefficients (ICC2,k) examined test-retest reliability of discrete parameters and PCA derived scores (PC-scores). ICC2,k values ranged from 0.57 to 0.93 for discrete parameters, 0.52-0.86 for knee angle PC-scores and 0.30-0.94 for the knee moment PC-scores. However, 10 of 13 discrete parameters, six of nine knee angle PC-scores and seven of nine knee moment PC-scores had ICC2,k values greater than or equal to 0.70. Discrete parameters and PC-scores from flexion angles and adduction moments had the highest ICC2,k values while adduction angles, rotation angles, and rotation moments had the lowest. Most knee angle and moment waveform characteristics demonstrated ICC2,k values that could be interpreted as acceptable. Caution should be used when examining adduction and rotation angle magnitudes and early/mid-stance rotation moment magnitudes due to lower ICC2,k values.

摘要

步态测量用于评估膝骨关节炎(OA)患者的变化,但在该人群中尚未完全确定其可靠性。本研究检查了使用离散参数和主成分分析(PCA)在中度膝 OA 患者中捕获的膝关节角度和力矩步态波形特征的测试 - 再测试可靠性。参与者(n=20)在两次进行三维步态分析。运动和力数据使用两个相机库、红外发光二极管和力板在自我选择的步行过程中进行捕获。使用离散参数和通过使用 PCA 识别波形特征来计算和分析膝关节角度和力矩波形。组内相关系数(ICC2,k)检查了离散参数和 PCA 衍生分数(PC-分数)的测试 - 再测试可靠性。离散参数的 ICC2,k 值范围为 0.57 至 0.93,膝关节角度 PC-分数为 0.52-0.86,膝关节力矩 PC-分数为 0.30-0.94。然而,13 个离散参数中有 10 个,9 个膝关节角度 PC-分数中有 6 个,9 个膝关节力矩 PC-分数中有 7 个的 ICC2,k 值大于或等于 0.70。来自屈曲角度和内收力矩的离散参数和 PC-分数具有最高的 ICC2,k 值,而内收角度、旋转角度和旋转力矩具有最低的 ICC2,k 值。大多数膝关节角度和力矩波形特征的 ICC2,k 值可以解释为可接受的。由于 ICC2,k 值较低,因此在检查内收和旋转角度幅度以及早期/中期站立旋转力矩幅度时应谨慎。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验