Suppr超能文献

反转恢复梯度回波与反转恢复快速自旋回波技术在马匹舟状骨髓病变磁共振成像检测中的比较

Comparison of inversion recovery gradient echo with inversion recovery fast spin echo techniques for magnetic resonance imaging detection of navicular bone marrow lesions in horses.

作者信息

Olive Julien, Vila Thibault, Serraud Nicolas

机构信息

Diagnostic Imaging Department, Faculty of Veterinary Medicine, University of Montreal, St-Hyacinthe, QC J2S 7C6, Canada.

出版信息

Am J Vet Res. 2013 Feb;74(2):232-8. doi: 10.2460/ajvr.74.2.232.

Abstract

OBJECTIVE

To compare navicular bone marrow lesion (BML) conspicuity in the feet of horses as determined via 2 fat-suppressed MRI techniques, including standard short tau inversion recovery (STIR) and inversion recovery gradient echo (IRGE).

SAMPLE

Feet (n = 150) of horses with lameness referable to the distal portion of the digit.

PROCEDURES

STIR and IRGE sequences were obtained prospectively in all feet with a standing low-field equine MRI system. Presence of a BML was ascertained by identification of a characteristic combination of marrow alterations in T1-weighted, T2*-weighted, T2-weighted, and STIR images. Signal-to-noise and contrast-to-noise ratios were calculated on STIR and IRGE sequences in 56 feet with a navicular BML.

RESULTS

Signal-to-noise and contrast-to-noise ratios of both sequences correlated linearly (r = 0.87 and r = 0.92, respectively) but were significantly higher for STIR images (mean ± SD, 22.6 ± 12.7 and 12.4 ± 11.4, respectively), compared with IRGE images (13.7 ± 8.0 and 5.9 ± 7.2, respectively).

CONCLUSIONS AND CLINICAL RELEVANCE

Results suggested that the IRGE sequence revealed BMLs significantly less conspicuously, compared with the standard STIR sequence. The 2 techniques cannot be used interchangeably, and IRGE is therefore not recommended as the sole fat-suppressed sequence for routine equine standing MRI protocols.

摘要

目的

通过两种脂肪抑制磁共振成像(MRI)技术,即标准短tau反转恢复序列(STIR)和反转恢复梯度回波序列(IRGE),比较马足部舟状骨髓病变(BML)的显影情况。

样本

因蹄趾远端跛行的马的蹄部(n = 150)。

步骤

使用站立式低场马用MRI系统对所有蹄部前瞻性地获取STIR和IRGE序列。通过在T1加权、T2*加权、T2加权和STIR图像中识别骨髓改变的特征组合来确定BML的存在。在56只存在舟状BML的蹄部上,计算STIR和IRGE序列的信噪比和对比噪声比。

结果

两个序列的信噪比和对比噪声比呈线性相关(分别为r = 0.87和r = 0.92),但与IRGE图像(分别为13.7 ± 8.0和5.9 ± 7.2)相比,STIR图像的这些值显著更高(分别为22.6 ± 12.7和12.4 ± 11.4)。

结论及临床意义

结果表明,与标准STIR序列相比,IRGE序列显示BML的显影明显较差。这两种技术不能互换使用,因此不建议将IRGE作为常规马站立式MRI方案的唯一脂肪抑制序列。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验