Suppr超能文献

[透析膜对内毒素的通透性。临床与实验结果]

[Permeability of dialysis membranes for endotoxins. Clinical and experimental results].

作者信息

Passavanti G, Buongiorno E, De Fino G, Fumarola D, Coratelli P

机构信息

Institute of Nephrology, Institute of Microbiology, University of Bari, Italy.

出版信息

Cas Lek Cesk. 1990 Mar 9;129(10):289-91.

PMID:2340547
Abstract

In the presented investigation in 20 endotoxaemic patients 70 haemodialyses were performed. It was revealed that the prehaemodialyzation LAL positivity in 50 haemodialyses (71%) declined, while no differences were observed in the effectiveness of cuprophan and AN 69 membranes. Research in vitro revealed that LAL positivity of blood which contains endotoxins and is subjected for 300 minutes to haemofiltration remains unaltered; in ultrafiltrates LAL is permanently negative. This is due to a mechanism of endotoxin fragmentation as a result of interaction of blood and membrane. Moreover, the LAL positivity of blood containing lipid A declines gradually when subjected to 80 minutes haemofiltration; the dialyzation permeability for lipid A is then proved by the fact that LAL positivity appears in the ultrafiltrate. From the submitted results ensues that reduction of LAL positivity by haemodialysis occurs as a result of elimination of filtrable endotoxin fragments (lipid A) which are released in the body.

摘要

在对20例内毒素血症患者进行的研究中,共进行了70次血液透析。结果显示,50次血液透析(71%)的透析前鲎试剂阳性率下降,而铜仿膜和AN 69膜的有效性未观察到差异。体外研究表明,含有内毒素并进行300分钟血液滤过的血液鲎试剂阳性率保持不变;超滤液中的鲎试剂始终为阴性。这是由于血液与膜相互作用导致内毒素碎片化的机制。此外,含有脂多糖A的血液在进行80分钟血液滤过时,其鲎试剂阳性率逐渐下降;超滤液中出现鲎试剂阳性这一事实证明了脂多糖A的透析通透性。根据提交的结果可知,血液透析导致鲎试剂阳性率降低是由于体内释放的可滤过内毒素片段(脂多糖A)被清除。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验