The aim of the present study was to quantitatively assess the relevance of transparency and refractive index (RI) on protein particle analysis by the light-based techniques light obscuration (LO) and Micro-Flow Imaging (MFI). A novel method for determining the RI of protein particles was developed and provided an RI of 1.41 for protein particles from two different proteins. An increased RI of the formulation by high protein concentration and/or sugars at pharmaceutically relevant levels was shown to lead to a significant underestimation of the subvisible particle concentration determined by LO and MFI. An RI match even caused particles to become "invisible" for the system, that is, not detectable anymore by LO and MFI. To determine the influence of formulation RI on particle measurements, we suggest the use of polytetrafluoroethylene (PTFE) particles to test a specific formulation for RI effects. In case of RI influences, we recommend also using a light-independent technique such as resonant mass measurement (RMM) (Archimedes) for subvisible particle analysis in protein formulations.

摘要

本研究的目的是定量评估光散射(LO)和微流成像(MFI)等基于光的技术中透明度和折射率(RI)对蛋白质颗粒分析的相关性。开发了一种用于确定蛋白质颗粒 RI 的新方法,该方法为两种不同蛋白质的蛋白质颗粒提供了 1.41 的 RI。结果表明,制剂的 RI 随着蛋白质浓度和/或在药学相关水平的糖的增加而增加,这会导致 LO 和 MFI 测定的亚可见颗粒浓度的严重低估。RI 匹配甚至会导致颗粒对系统“不可见”,即 LO 和 MFI 无法再检测到。为了确定制剂 RI 对颗粒测量的影响,我们建议使用聚四氟乙烯(PTFE)颗粒来测试特定制剂的 RI 影响。在存在 RI 影响的情况下,我们还建议使用光独立技术(如谐振质量测量(RMM)(阿基米德))来分析蛋白质制剂中的亚可见颗粒。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验