Mayo Clinic, Rochester, Minnesota 55905, USA.
J Arthroplasty. 2013 May;28(5):818-23. doi: 10.1016/j.arth.2012.11.006. Epub 2013 Mar 15.
White blood cell (WBC) count and neutrophil percentage from preoperative synovial fluid aspirations are used to help determine the presence or absence of periprosthetic joint infection (PJI) in failed total hip arthroplasty (THA). The clinical levels indicative of infection have not been delineated in metal-on-metal (MoM) bearings. We identified 39 patients who received a preoperative synovial fluid aspiration prior to MoM revision. Thirty-five of 39 cases were culture negative and 4 of 39 were culture positive. WBC count >3000 cells/μL was 100% sensitive and 57.1% specific. Neutrophil percentage >80% was 100% sensitive and 97.1% specific. Both CRP and ESR >8.0mg/L and >22 mm/h, respectively were 75.0% sensitive and 67.6% specific. Our data suggest that synovial WBC count and serum ESR and CRP have poor predictive value in diagnosing PJI for failed MoM THA, whereas synovial neutrophil percentage is a highly accurate marker for diagnosing infection in this patient population.
术前关节滑液抽吸的白细胞 (WBC) 计数和中性粒细胞百分比用于帮助确定失败的全髋关节置换术 (THA) 中是否存在假体周围关节感染 (PJI)。在金属对金属 (MoM) 轴承中,尚未确定感染的临床指征。我们确定了 39 名在 MoM 翻修前接受术前关节滑液抽吸的患者。39 例中有 35 例培养结果为阴性,39 例中有 4 例培养结果为阳性。WBC 计数 >3000 个/μL 的敏感性为 100%,特异性为 57.1%。中性粒细胞百分比 >80%的敏感性为 100%,特异性为 97.1%。CRP 和 ESR 分别>8.0mg/L 和 >22mm/h 的敏感性分别为 75.0%和 67.6%。我们的数据表明,对于失败的 MoM THA,关节滑液 WBC 计数和血清 CRP 和 ESR 的预测价值较低,而关节滑液中性粒细胞百分比是诊断该患者人群感染的高度准确标志物。