Suppr超能文献

Evaluation of radon mitigation systems in 14 houses over a two-year period.

作者信息

Prill R J, Fisk W J, Turk B H

机构信息

Lawrence Berkeley Laboratory, Berkeley, California.

出版信息

J Air Waste Manage Assoc. 1990 May;40(5):740-8. doi: 10.1080/10473289.1990.10466719.

Abstract

Fourteen single-family detached houses in Spokane, Washington, and Coeur D'Alene, Idaho, were monitored for two years after high concentrations of indoor radon had been mitigated. Each house was monitored quarterly using mailed alpha-track radon detectors deployed in each zone of the structure. To assess performance of mitigation systems during the second heating season after mitigation, radon concentrations in seven houses were monitored continuously for several weeks, mitigation systems in all houses were inspected, and selected other measurements were taken. In addition, occupants were also interviewed regarding their maintenance, operation, and subjective evaluation of the radon mitigation systems. Quarterly alpha-track measurements showed that radon levels had increased in most of the homes during many follow-up measurement periods when compared with concentrations measured immediately after mitigation. Mitigation-system performance was adversely affected by (1) accumulated outdoor debris blocking the outlets of subsurface pressurization pipes; (2) fans being turned off (e.g., because of excessive noise or vibration); (3) air-to-air heat exchanger, basement pressurization, and subsurface ventilation fans being turned off and fan speeds reduced; and (4) crawl-space vents being closed or sealed.