Suppr超能文献

亮度在腰椎椎弓根螺钉位置评估中的作用:临床研究

Effect of brightness in the evaluation of lumbar pedicular screws position: clinical study.

作者信息

Romero-Muñoz L M, Alfonso M, Villas C, Zubieta J L

机构信息

Department of Orthopedics, University Clinic of Navarra, Avenida de Pio XII, 36, 31008, Pamplona, Navarra, Spain.

出版信息

Musculoskelet Surg. 2013 Aug;97(2):159-64. doi: 10.1007/s12306-013-0248-1. Epub 2013 Apr 5.

Abstract

Artifact may lead to confusion when evaluating postoperative CT scans of lumbar pedicle screws. The aim of our study was to develop a specific metal artifact reduction image protocol, in order to reduce metal artifact caused by titanium pedicular screw in patients undergoing lumbar pathology by lumbar fusion. Therefore, the reduction in metal artifacts in lumbar pedicle screws allows surgeons to do an accurate diagnosis of the exact placement of inserted pedicle screws, minimizes false reexploration, and maximizes proper and prompt treatment of misplaced screw. In a first step, we performed a retrospective study of 103 titanium alloy pedicle screws in patients undergoing a lumbar instrumented fusion for treatment for degenerative disease. CT scan was performed postoperatively evaluating the possible overdimension caused by artifact. In a second step, a prospective study was performed using a 64-slice multidetector-row computed tomography (MDCT) in 104 titanium alloy pedicle screws in patients undergoing a lumbar instrumented fusion for treatment for degenerative disease. Our results show that on the group of sequential CT scan, mean overdimension (on each side) due to brightness was 1.045 mm (SD 0.45). On the group of 64-slice multichannel CT, mean overdimension (on each side) due to brightness was 0.005 mm at the proximal part of the screw and 0.025 mm at the distal part of the screw. The results observed suggest that beam-hardening artifacts caused by the screw on CT after lumbar fusion are dramatically reduced by using specific metal artifact reduction image protocol in a 64-slice MDCT.

摘要

在评估腰椎椎弓根螺钉的术后CT扫描时,伪影可能会导致混淆。我们研究的目的是开发一种特定的减少金属伪影的图像协议,以减少腰椎融合治疗腰椎疾病患者中钛椎弓根螺钉引起的金属伪影。因此,减少腰椎椎弓根螺钉中的金属伪影可使外科医生准确诊断植入椎弓根螺钉的精确位置,最大限度地减少错误的再次探查,并最大限度地正确及时治疗位置不当的螺钉。第一步,我们对103例接受腰椎器械融合治疗退行性疾病患者的钛合金椎弓根螺钉进行了回顾性研究。术后进行CT扫描,评估伪影可能导致的尺寸过大情况。第二步,对104例接受腰椎器械融合治疗退行性疾病患者的钛合金椎弓根螺钉,使用64层多排螺旋计算机断层扫描(MDCT)进行前瞻性研究。我们的结果显示,在连续CT扫描组中,由于亮度导致的平均尺寸过大(每侧)为1.045毫米(标准差0.45)。在64层多通道CT组中,螺钉近端由于亮度导致的平均尺寸过大(每侧)为0.005毫米,螺钉远端为0.025毫米。观察到的结果表明,在腰椎融合术后的CT上由螺钉引起的束硬化伪影通过在64层MDCT中使用特定的减少金属伪影的图像协议可显著减少。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验