Suppr超能文献

评价 3M Petrifilm 在场环境培养系统在泌乳期末检测乳房内感染的应用。

Evaluation of a 3M Petrifilm on-farm culture system for the detection of intramammary infection at the end of lactation.

机构信息

Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, 550 University Avenue, Charlottetown, PEI C1A 4P3, Canada.

出版信息

Prev Vet Med. 2013 Aug 1;111(1-2):1-9. doi: 10.1016/j.prevetmed.2013.03.006. Epub 2013 Apr 15.

Abstract

The purpose of this study was to evaluate a 3M Petrifilm-based on-farm culture system for the detection of intramammary infection (IMI) in low somatic cell count (SCC) cows (<200,000 cells/mL) at drying off. The main objectives were to determine the test characteristics and the predictive values of the Petrifilm on-farm culture system. The ability of dairy producers to correctly classify cows as infected or uninfected based on Petrifilm culture and a set colony count threshold was also assessed. A total of 360 cows originating from 16 low bulk tank SCC (<250,000 cells/mL) dairy herds were enrolled at drying off. Enrolled cows had an expected dry period of 30-90 days, a SCC<200,000 cells/mL on the last 3 tests prior to drying off, no clinical mastitis in the same time period, and no antibiotic treatment in the last 14 days. Quarter milk samples were collected on the day prior to drying off, and a composite milk sample was created by combining 5 mL of milk from each quarter sample. Composite milk samples were cultured on-farm using the Petrifilm culture system, which provided results within 24h. Quarter milk samples were cultured in a reference laboratory, and the results were aggregated to the cow level. On the day of drying off, the Petrifilm was read by the producer and cows were classified as positive if ≥5 colonies (equivalent to 50 colony forming units/mL) were present. When read by the producer, 47.8% of the cows cultured negative on Petrifilm and were infused with only an internal teat sealant at drying off. The test characteristics of the Petrifilm on-farm culture system were calculated by comparing the producer-derived Petrifilm results to those obtained by standard laboratory culture. The sensitivity and specificity of the Petrifilm on-farm culture system were 85.2% (78.5-90.5) and 73.2% (66.4-79.3), respectively. The negative predictive value of the Petrifilm test system was high (86.6%) when estimated using the prevalence of IMI in this data set, and the positive predictive value was moderate (70.9%). An automated 3M Petrifilm reader was used to obtain accurate colony counts. The agreement between Petrifilm results obtained by the producer and those obtained by the automated Petrifilm reader was high, with a kappa value of 0.82 (0.75-0.89).

摘要

本研究旨在评估 3M Petrifilm 基于农场的培养系统,用于检测干奶期低体细胞计数(SCC)奶牛(<200,000 个细胞/ml)的隐性乳房炎。主要目的是确定 Petrifilm 农场培养系统的检测特征和预测值。还评估了奶农根据 Petrifilm 培养和设定的菌落计数阈值正确分类奶牛感染或未感染的能力。共纳入了 360 头来自 16 个低批量 SCC(<250,000 个细胞/ml)奶牛场的奶牛,在干奶期结束时进行了检测。纳入的奶牛预期干奶期为 30-90 天,在上次 3 次干奶前检测中 SCC<200,000 个细胞/ml,在同一时期无临床乳腺炎,且在过去 14 天内无抗生素治疗。在干奶前一天采集每个乳房的 5ml 牛奶进行混合,形成复合奶样。在农场使用 Petrifilm 培养系统进行培养,24 小时内可获得结果。将奶牛的乳房奶样送到参考实验室进行培养,将结果汇总到奶牛水平。在干奶当天,由生产者读取 Petrifilm 的结果,如果有≥5 个菌落(相当于 50 个菌落形成单位/ml),则将奶牛判定为阳性。当由生产者读取时,Petrifilm 培养结果为阴性的奶牛有 47.8%,仅在干奶时使用内部乳头密封剂。通过比较生产者获得的 Petrifilm 结果和标准实验室培养结果,计算了 Petrifilm 农场培养系统的检测特征。Petrifilm 农场培养系统的敏感性和特异性分别为 85.2%(78.5-90.5)和 73.2%(66.4-79.3)。当使用本数据集的隐性乳房炎流行率估计时,Petrifilm 检测系统的阴性预测值较高(86.6%),阳性预测值中等(70.9%)。使用自动 3M Petrifilm 读数器可获得准确的菌落计数。生产者获得的 Petrifilm 结果与自动 Petrifilm 读数器获得的结果之间的一致性很高,kappa 值为 0.82(0.75-0.89)。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验