Suppr超能文献

电组织阻抗光谱法:一种在内镜检查期间测量食管黏膜完整性变化的新型设备。

Electrical tissue impedance spectroscopy: a novel device to measure esophageal mucosal integrity changes during endoscopy.

作者信息

Weijenborg P W, Rohof W O A, Akkermans L M A, Verheij J, Smout A J P M, Bredenoord A J

机构信息

Department of Gastroenterology and Hepatology, Academic Medical Center, Amsterdam, The Netherlands.

出版信息

Neurogastroenterol Motil. 2013 Jul;25(7):574-8, e457-8. doi: 10.1111/nmo.12106. Epub 2013 Mar 11.

Abstract

BACKGROUND

Patients with gastroesophageal reflux disease (GERD) have impaired esophageal mucosal integrity. Measurement of the mucosal integrity is complex and time-consuming. Electrical tissue impedance spectroscopy (ETIS) is a device that measures impedance of tissue in vivo during endoscopy. In this study, we aimed to validate ETIS as a measure of esophageal mucosal integrity.

METHODS

Electrical tissue impedance spectroscopy measurements were performed during upper endoscopy in 12 GERD patients and 11 healthy controls after cessation of proton pump inhibition. During endoscopy biopsies of the distal esophagus were obtained for transmission electron microscopy to determine dilation of intercellular spaces (DIS) and for Ussing chamber experiments to determine transepithelial permeability and transepithelial electrical resistance.

KEY RESULTS

Extracellular impedance measured in vivo by ETIS was significantly lower in GERD patients compared to controls [mean (SD) 5621 (3299) Ω.m and 8834 (2542) Ω.m, respectively, P < 0.05]. We found a strong inverse relation between extracellular impedance determined by ETIS and DIS (r = -0.76, P < 0.05), and between extracellular resistance in vivo and transepithelial permeability of esophageal biopsies (r = -0.65, P < 0.01).

CONCLUSIONS & INFERENCES: Electrical tissue impedance spectroscopy is a new tool that can be used to evaluate esophageal mucosal integrity changes during endoscopy.

摘要

背景

胃食管反流病(GERD)患者的食管黏膜完整性受损。黏膜完整性的测量复杂且耗时。电组织阻抗光谱法(ETIS)是一种在内镜检查期间测量体内组织阻抗的设备。在本研究中,我们旨在验证ETIS作为食管黏膜完整性测量方法的有效性。

方法

在12例GERD患者和11名健康对照者停止使用质子泵抑制剂后进行上消化道内镜检查时,采用电组织阻抗光谱法进行测量。在内镜检查期间,获取食管远端活检组织用于透射电子显微镜检查以确定细胞间隙扩张(DIS),并用于尤斯灌流小室实验以确定跨上皮通透性和跨上皮电阻。

主要结果

与对照组相比,GERD患者经ETIS在体内测量的细胞外阻抗显著降低[分别为平均(标准差)5621(3299)Ω·m和8834(2542)Ω·m,P < 0.05]。我们发现ETIS测定的细胞外阻抗与DIS之间存在强负相关(r = -0.76,P < 0.05),以及体内细胞外电阻与食管活检组织的跨上皮通透性之间存在强负相关(r = -0.65,P < 0.01)。

结论与推论

电组织阻抗光谱法是一种可用于在内镜检查期间评估食管黏膜完整性变化的新工具。