Abstract

Wedged insoles may produce immediate effects on knee abduction angular impulses during running; however, it is currently not known whether these knee abduction angular impulse magnitudes are maintained throughout a run when fatigue sets in. If changes occur, this could affect the clinical utility of wedged insoles in treating conditions such as patellofemoral pain. Thus, the purpose of this study was to determine whether knee abduction angular impulses are altered during a prolonged run with wedged insoles. It was hypothesized that knee abduction angular impulses would be reduced following a prolonged run with wedged insoles. Nine healthy runners participated. Runners were randomly assigned to either a 6-mm medial wedge condition or a 6-mm lateral wedge condition and then ran continuously overground for 30 min. Knee abduction angular impulses were quantified at 0 and 30 min using a gait analysis procedure. After 2 days, participants returned to perform the same test but with the other wedge type. Two-way repeated-measures analysis of variance was used to evaluate main effects of wedge condition and time and interactions between wedge condition and time (α = 0.05). Paired t-tests were used for post hoc analysis (α = 0.01). No interaction effects (p = 0.958) were found, and knee abduction angular impulses were not significantly different over time (p = 0.384). Lateral wedge conditions produced lesser knee abduction angular impulses than medial conditions at 0 min (difference of 2.79 N m s, p = 0.006) and at 30 min (difference of 2.76 N m s, p < 0.001). It is concluded that significant knee abduction angular impulse changes within wedge conditions do not occur during a 30-min run. Additionally, knee abduction angular impulse differences between wedge conditions are maintained during a 30-min run.

摘要

楔形鞋垫可能会在跑步过程中对膝关节外展角冲量产生即时影响;然而,目前尚不清楚当疲劳出现时,这些膝关节外展角冲量的大小在整个跑步过程中是否会保持不变。如果发生变化,这可能会影响楔形鞋垫在治疗髌股疼痛等病症中的临床效用。因此,本研究的目的是确定在长时间穿着楔形鞋垫跑步期间,膝关节外展角冲量是否会发生改变。研究假设是,长时间穿着楔形鞋垫跑步后,膝关节外展角冲量会降低。九名健康跑步者参与了研究。跑步者被随机分配到6毫米内侧楔形条件组或6毫米外侧楔形条件组,然后在地面上连续跑30分钟。使用步态分析程序在0分钟和30分钟时对膝关节外展角冲量进行量化。两天后,参与者返回进行相同测试,但使用另一种楔形类型。采用双向重复测量方差分析来评估楔形条件和时间的主要影响以及楔形条件和时间之间的相互作用(α = 0.05)。配对t检验用于事后分析(α = 0.01)。未发现相互作用效应(p = 0.958),并且膝关节外展角冲量随时间没有显著差异(p = 0.384)。在0分钟时(差异为2.79 N·m·s,p = 0.006)和30分钟时(差异为2.76 N·m·s,p < 0.001),外侧楔形条件组产生的膝关节外展角冲量小于内侧条件组。得出的结论是,在30分钟的跑步过程中,楔形条件内膝关节外展角冲量没有显著变化。此外,在30分钟的跑步过程中,楔形条件之间的膝关节外展角冲量差异保持不变。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验