二维斑点追踪超声心动图与三维计算机断层成像技术对左心房结构和功能的定量验证:一项比较研究。

Quantitative validation of left atrial structure and function by two-dimensional and three-dimensional speckle tracking echocardiography: a comparative study with three-dimensional computed tomography.

机构信息

Department of Cardiology, Gifu Prefectural General Medical Center, Gifu, Japan.

出版信息

J Cardiol. 2013 Sep;62(3):188-94. doi: 10.1016/j.jjcc.2013.03.011. Epub 2013 May 11.

Abstract

BACKGROUND

The aim of this study was to validate the accuracy of three-dimensional (3D) speckle tracking echocardiography (STE) and two-dimensional (2D)-STE for the assessment of left atrial (LA) volume and function by comparison with 3D-computed tomography (CT) performed on the same day as STE.

METHODS

LA phasic volume and emptying function (EF) were measured in 28 patients with paroxysmal atrial fibrillation undergoing catheter ablation (62±11 years old) using both 3D-STE and 2D-STE during sinus rhythm. LA phasic volume and function measured by 3D-STE and 2D-STE were validated using 3D-CT as a gold standard.

RESULTS

The intraobserver correlation coefficient and variability in maximum LA volume assessed by 3D-STE were 0.99 and 1.4±6.0%, respectively. The interobserver correlation coefficient and variability in maximum LA volume assessed by 3D-STE were 0.99 and 0.2±4.5%, respectively. There were strong correlations between LA phasic volume measured by 3D-CT and those measured by 3D-STE (r=0.98, p<0.001). There were correlations between LA phasic function measured by 3D-CT and those measured by 3D-STE (r=0.85-0.88, p<0.001). There was a better agreement between 3D-CT and 3D-STE in the assessment of LA phasic volumes and function than between 3D-CT and 2D-STE in apical 2- and 4-chamber view.

CONCLUSIONS

3D-STE allows more accurate measurement of LA volume and function than 2D-STE and has high reproducibility.

摘要

背景

本研究旨在通过与同一天进行的三维(3D)计算机断层扫描(CT)比较,验证三维斑点追踪超声心动图(STE)和二维(2D)-STE 评估左心房(LA)容积和功能的准确性。

方法

在 28 例阵发性心房颤动行导管消融术的患者中(62±11 岁),在窦性心律下使用 3D-STE 和 2D-STE 测量 LA 时相容积和排空功能(EF)。使用 3D-CT 作为金标准验证通过 3D-STE 和 2D-STE 测量的 LA 时相容积和功能。

结果

3D-STE 评估最大 LA 容积的观察者内相关系数和变异性分别为 0.99 和 1.4±6.0%。3D-STE 评估最大 LA 容积的观察者间相关系数和变异性分别为 0.99 和 0.2±4.5%。3D-CT 测量的 LA 时相容积与 3D-STE 测量的容积之间存在很强的相关性(r=0.98,p<0.001)。3D-CT 测量的 LA 时相功能与 3D-STE 测量的功能之间存在相关性(r=0.85-0.88,p<0.001)。与 3D-CT 和 2D-STE 在心尖 2 腔和 4 腔视图相比,3D-CT 和 3D-STE 在评估 LA 时相容积和功能方面具有更好的一致性。

结论

3D-STE 比 2D-STE 更能准确测量 LA 容积和功能,且具有更高的可重复性。