Kumar P P, Good R R, McCaul G F
Division of Radiation Oncology, University of Nebraska Medical Center, Omaha 68105.
Int J Radiat Oncol Biol Phys. 1990 Jun;18(6):1509-11. doi: 10.1016/0360-3016(90)90328-h.
A modified afterloading Kumar Cervical Applicator with a 3 mm diameter central tandem permits insertion of the afterloading tandem into the uterus without need of manual cervical dilatation. While general anesthesia is required for insertion of standard cervical applicators, this is eliminated because the central tandem is no larger than a uterine sound, and the tandem may be painlessly inserted into the uterus while the patient is awake.
一种改良的后装式库马尔宫颈施源器,其中心穿棒直径为3毫米,无需手动扩张宫颈即可将后装穿棒插入子宫。插入标准宫颈施源器需要全身麻醉,而这种情况得以避免,因为中心穿棒不大于子宫探子,并且在患者清醒时可将穿棒无痛插入子宫。