Monash Cardiovascular Research Centre, MonashHEART, Southern Health & Department of Medicine (MMC), Monash University, Melbourne, Australia.
Heart Lung Circ. 2013 Sep;22(9):784-5. doi: 10.1016/j.hlc.2013.04.118. Epub 2013 May 20.
Percutaneous left atrial appendage (LAA) occlusion is commonly performed using umbrella-shaped devices. However, the utility of such devices is highly dependent on the underlying anatomy of the appendage. For the first time, we report the use of an Occlutech PFO closure device to successfully occlude a left atrial appendage that possessed a circumferential ridge at its mouth. PFO closure devices would also be suitable for the occlusion of left atrial appendages when an incomplete surgical closure results in a circumferential ridge.
经皮左心耳(LAA)封堵术通常采用伞状装置进行。然而,此类装置的实用性高度依赖于心耳的基础解剖结构。我们首次报告了使用 Occlutech PFO 封堵装置成功封堵具有环形嵴的心耳。当不完全的手术封堵导致环形嵴时,PFO 封堵装置也可适用于左心耳的封堵。