Department of Clinical Dentistry - Biomaterials, Faculty of Medicine and Dentistry, University of Bergen, Norway.
Dent Mater. 2013 Aug;29(8):815-23. doi: 10.1016/j.dental.2013.04.026. Epub 2013 Jun 6.
Fracture strength measured in vitro indicates that most all-ceramic crowns should be able to withstand mastication forces. Nevertheless, fractures are one of the major clinical problems with all-ceramic restorations. Furthermore, the fracture mode of all-ceramic crowns observed in clinical use differs from that found in conventional fracture strength tests. The aim of the present study was to develop and investigate a method that simulates clinical fracture behavior in vitro.
30 crowns with alumina cores were made to fit a cylindrical model with a molar-like preparation design. These crowns were randomly allocated to 3 tests groups (n=10). The crowns in group 1 were cemented to abutment models of epoxy and subsequently fractured by occlusal loading without contact damage. The crowns in group 2 were fractured by cementation with expanding cement. The crowns in group 3 were cemented on an abutment model of epoxy split almost in two and fractured by increasing the diameter of the model in the bucco-lingual direction. The fractured crowns were analyzed by fractographic methods and compared to a reference group of 10 crowns fractured in clinical use.
The fracture modes of all the in vitro crowns were similar to clinical fracture modes. The fracture modes in group 1 were most closely matched to the clinical fractures. These crowns also fractured at clinically relevant loads.
Laboratory tests that induce a distortion of the abutment model during occlusal loading without occlusal contact damage can simulate clinical fractures of all-ceramic crowns.
体外测量的断裂强度表明,大多数全瓷冠应该能够承受咀嚼力。然而,骨折是全瓷修复体的主要临床问题之一。此外,在临床使用中观察到的全瓷冠的断裂模式与传统断裂强度测试中发现的断裂模式不同。本研究的目的是开发和研究一种在体外模拟临床骨折行为的方法。
制作 30 个带有氧化铝芯的牙冠,以适合具有类似磨牙制备设计的圆柱形模型。这些牙冠被随机分配到 3 个测试组(n=10)。第 1 组牙冠粘接到环氧基底模型上,然后通过无接触损伤的咬合加载使其断裂。第 2 组牙冠通过膨胀水泥粘结后断裂。第 3 组牙冠粘接到环氧基底模型上,模型几乎分成两半,然后通过增加模型在颊舌方向的直径使其断裂。用断口分析方法对断裂的牙冠进行分析,并与 10 个在临床使用中断裂的牙冠参考组进行比较。
所有体外牙冠的断裂模式与临床断裂模式相似。第 1 组的断裂模式与临床骨折最吻合。这些牙冠也在临床相关负荷下断裂。
在无咬合接触损伤的情况下,通过对基底模型进行咬合加载导致变形的实验室测试可以模拟全瓷冠的临床骨折。