Suppr超能文献

随机比较 Pentax AirWay 喉镜和 Macintosh 喉镜在阻塞性睡眠呼吸暂停患者中的气管插管。

Randomized comparison of the Pentax AirWay Scope and Macintosh laryngoscope for tracheal intubation in patients with obstructive sleep apnoea.

机构信息

Department of Anesthesiology and Pain Medicine, School of Medicine, Kyung Hee University, 23 Kyungheedae-ro, Dongdaemun-gu, Seoul 130-872, Republic of Korea.

出版信息

Br J Anaesth. 2013 Oct;111(4):662-6. doi: 10.1093/bja/aet201. Epub 2013 Jun 9.

Abstract

BACKGROUND

Patients with obstructive sleep apnoea (OSA) can often present difficulties in intubation. This study aimed to compare the efficacy of the Pentax AirWay Scope (AWS) with that of the Macintosh laryngoscope for tracheal intubation in patients with OSA.

METHODS

Forty-six patients undergoing uvulopalatopharyngoplasty were randomly allocated to tracheal intubation with either the Macintosh laryngoscope or the Pentax AWS. In all patients, intubation was performed by one of two anaesthetists experienced with both devices. The primary and secondary endpoints of this study were the intubation difficulty scale (IDS) score and success/failure and duration of the first successful intubation attempt.

RESULTS

With the Pentax AWS, tracheal intubation was successful on the first attempt in all patients whereas four patients required repeated attempts at intubation with the Macintosh laryngoscope. The IDS score was significantly lower using the Pentax AWS and glottic exposure was better (the Cormack and Lehane grade 1 in all patients vs grade 2 or higher in all patients, P<0.0001). Average duration of successful intubation was shorter (12.9 vs 29.9 s, P=0.0002), and fewer manoeuvres were needed to improve the glottic exposure (0 in all patients vs 1 or more in 16 patients, P<0.0001) with the Pentax AWS, compared with the Macintosh laryngoscope.

CONCLUSIONS

In this study of patients with OSA, tracheal intubation by experienced anaesthetists was facilitated using the Pentax AWS compared with the Macintosh laryngoscope.

摘要

背景

阻塞性睡眠呼吸暂停(OSA)患者常存在插管困难。本研究旨在比较 Pentax AirWay Scope(AWS)与 Macintosh 喉镜用于 OSA 患者气管插管的效果。

方法

46 例行悬雍垂腭咽成形术的患者被随机分为使用 Macintosh 喉镜或 Pentax AWS 进行气管插管。所有患者均由两位有使用这两种设备经验的麻醉医师进行插管。本研究的主要和次要终点为插管难度评分(IDS)和首次成功插管的成功/失败和持续时间。

结果

使用 Pentax AWS,所有患者均首次成功插管,而 4 例患者需要反复尝试 Macintosh 喉镜插管。使用 Pentax AWS 时 IDS 评分显著降低,声门显露更好(所有患者均为 Cormack 和 Lehane 1 级,而所有患者均为 2 级或更高)(P<0.0001)。成功插管的平均时间更短(12.9 秒 vs 29.9 秒,P=0.0002),并且需要改善声门显露的操作次数更少(所有患者均为 0 次,而 16 例患者中有 1 次或更多次,P<0.0001)(所有患者均为 0 次,而 16 例患者中有 1 次或更多次,P<0.0001)与 Macintosh 喉镜相比,使用 Pentax AWS 时。

结论

在这项 OSA 患者的研究中,与 Macintosh 喉镜相比,有经验的麻醉医师使用 Pentax AWS 进行气管插管更为方便。