着色颌面硅橡胶用增白剂和紫外线吸收剂的影响,第 2 部分:人工老化后的机械性能。

Effect of opacifiers and UV absorbers on pigmented maxillofacial silicone elastomer, part 2: mechanical properties after artificial aging.

机构信息

Department of Oral Health Sciences, Faculty of Dentistry, University of British Columbia, Vancouver, BC, Canada.

出版信息

J Prosthet Dent. 2013 Jun;109(6):402-10. doi: 10.1016/S0022-3913(13)60328-5.

Abstract

STATEMENT OF PROBLEM

There are reports of dissatisfaction with color instability and reduced lifetime of extraoral maxillofacial prostheses. Previous studies showed that UV mineral-based light-protecting agent (LP) improved color stability of MDX4-4210/Type A silicone elastomer. However, effects of this agent and opacifiers on mechanical properties of the elastomer are unknown.

PURPOSE

The purpose of this study was to evaluate the effect of 2 commonly used opacifiers and LP, a new opacifier, when combined with pigments on the mechanical properties of MDX4-4210/Type A silicone elastomer before and after artificial aging.

MATERIAL AND METHODS

Two commonly used opacifiers, titanium white dry pigment (TW) and silicone intrinsic white (SW) and LP were each combined with MDX4-4210/type A. Artists' oil pigment was then combined with the LP and TW groups, and silicone intrinsic pigments were combined with the SW group with 5 colors (no pigment=control, red, yellow, blue, or a combination of the 3 pigments). Ten dumbbell-shaped and 10 trouser-shaped specimens of each opacifier + pigment mixture, plus a control group with no opacifier and no pigment, were made for a total of 320 specimens. Half of the specimens (n=5) were aged in a chamber at 450 kJ/m(2). Specimens were tested for hardness (ASTM D2240), tensile strength (ASTM D412), tear strength (ASTM D624), and percentage elongation in a universal testing machine. A 3-way ANOVA and the Fisher PLSD test were performed (α=.05) for each mechanical property.

RESULTS

After accelerated aging, values of Shore A hardness were the lowest for LP with all 5 pigments and the control, followed by SW and TW (P<.001). After accelerated aging, tear strength, tensile strength, and elongation decreased significantly (P<.001) for LP, whereas changes for SW and TW varied depending on the pigment.

CONCLUSIONS

The mechanical properties of specimens with the light-protecting opacifier were adversely affected after being subjected to artificial aging. SW and TW preserved the mechanical properties of silicone in this study.

摘要

问题陈述

有报道称,口腔颌面赝复体的颜色稳定性和使用寿命不满意。先前的研究表明,UV 矿物基光保护剂(LP)提高了 MDX4-4210/A 型硅橡胶的颜色稳定性。然而,该剂和不透明剂对弹性体力学性能的影响尚不清楚。

目的

本研究的目的是评估两种常用的不透明剂和 LP(一种新的不透明剂)与颜料结合使用对 MDX4-4210/A 型硅橡胶人工老化前后力学性能的影响。

材料与方法

将两种常用的不透明剂钛白粉干颜料(TW)和硅酮内白(SW)与 LP 分别结合,然后将艺术家油颜料与 LP 和 TW 组结合,将硅酮内颜料与 SW 组结合,颜色为 5 种(无颜料=对照、红、黄、蓝或 3 种颜料的组合)。每组不透明剂+颜料混合物各制作 10 个哑铃形和 10 个裤形试件,外加无不透明剂和无颜料的对照组,共 320 个试件。将一半试件(n=5)在 450kJ/m2 的腔室内老化。在万能试验机上测试硬度(ASTM D2240)、拉伸强度(ASTM D412)、撕裂强度(ASTM D624)和伸长率。对每种力学性能进行三因素方差分析和 Fisher PLSD 检验(α=0.05)。

结果

加速老化后,含所有 5 种颜料和对照组的 LP 的邵氏 A 硬度值最低,其次是 SW 和 TW(P<.001)。加速老化后,LP 的撕裂强度、拉伸强度和伸长率显著降低(P<.001),而 SW 和 TW 的变化取决于颜料。

结论

经人工老化后,含光保护不透明剂的试件力学性能受到不利影响。SW 和 TW 在本研究中保持了硅橡胶的力学性能。