Institute of Chemistry of Sao Carlos, University of Sao Paulo, Postal Code 780, 13560-970 São Carlos, SP, Brazil.
J Chromatogr A. 2013 Jul 19;1299:126-30. doi: 10.1016/j.chroma.2013.05.023. Epub 2013 May 16.
Analysis of several emerging contaminants (steroids, caffeine and methylparaben) in water using automated solid-phase microextraction with comprehensive two dimensional gas chromatography coupled to time of flight mass spectrometry (SPME-GCxGC-ToF/MS) is presented. Experimental design was used to determine the best SPME extraction conditions and the steroids were not derivatized prior to injection. SPME-GCxGC-ToF/MS provided linear ranges from 0.6 to 1200μgL(-1) and limits of detection and quantitation from 0.02 to 100μgL(-1). A series of river water samples obtained locally were subjected to analysis. SPME-GCxGC-ToF/MS is readily automated, straightforward and competitive with other methods for low level analysis of emerging contaminants.
采用自动化固相微萃取-二维气相色谱-飞行时间质谱联用技术(SPME-GCxGC-ToF/MS)分析水中几种新兴污染物(甾体、咖啡因和甲基对羟基苯甲酸酯)。通过实验设计确定最佳 SPME 萃取条件,且在注入前无需对甾体进行衍生化处理。SPME-GCxGC-ToF/MS 提供了 0.6 至 1200μg/L 的线性范围,检测限和定量限为 0.02 至 100μg/L。对当地采集的一系列河水样本进行了分析。SPME-GCxGC-ToF/MS 易于自动化,操作简单,并且在痕量分析新兴污染物方面与其他方法具有竞争力。