评估一款即时检测凝血分析仪(Abaxis VSPro)用于识别犬类凝血病的情况。

Evaluation of a point-of-care coagulation analyzer (Abaxis VSPro) for identification of coagulopathies in dogs.

作者信息

Dixon-Jimenez Amy C, Brainard Benjamin M, Cathcart Curtis J, Koenig Amie

机构信息

Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, University of Georgia, Athens, GA 30602, USA.

出版信息

J Vet Emerg Crit Care (San Antonio). 2013 Jul-Aug;23(4):402-7. doi: 10.1111/vec.12064. Epub 2013 Jun 24.

Abstract

OBJECTIVE

To evaluate the ability of the Abaxis VSPro, a point-of-care analyzer that measures prothrombin time (PT) and activated partial thromboplastin time (aPTT), to identify dogs with coagulopathies caused by administration of anticoagulants.

SETTING

Veterinary teaching hospital.

ANIMALS

Six healthy adult dogs that are part of a preexisting research colony. One dog was not included in the warfarin portion of the study.

MEASUREMENTS AND MAIN RESULTS

Unfractionated heparin (UFH, 50 U/kg i.v. once then 300 U/kg s.q. q 8 h) was administered to prolong aPTT. Citrated whole blood was used for PT and aPTT analyses with the VSPro and were run in duplicate. The VSPro results were compared to PT and aPTT measured in plasma with a standard benchtop coagulometer (AMAX Destiny). A washout period of at least 24 hours followed. Once dogs had normal PT and aPTT values, warfarin was administered (0.25-0.30 mg/kg p.o.) once then (0.15 mg/kg p.o.) as needed up to every 12 hours to prolong PT values. Seventy separate samples were evaluated for PT and 73 samples for aPTT. Pearson correlation coefficients (PCC) for replicate VSPro measures of PT and aPTT were 0.941 and 0.891, respectively (P < 0.001). The PCC between VSPro and AMAX was 0.578 for PT and of 0.865 for PTT (P < 0.001). Receiver operating characteristic (ROC) analysis indicated a maximum sensitivity and specificity for diagnosis of coagulopathy (by AMAX) at VSPro PT value of 21.6 seconds (sensitivity 72%, specificity 86%) and a maximum sensitivity and specificity at VSPro aPTT of 105.3 seconds (sensitivity 93%, specificity 89%). The positive predictive value for PT and aPTT were 84% and 89%, respectively.

CONCLUSIONS

The Abaxis VSPro showed acceptable correlation with clinical laboratory tests, and is a useful POC device for identification of animals with abnormalities in PT or aPTT.

摘要

目的

评估即时检验分析仪Abaxis VSPro测定凝血酶原时间(PT)和活化部分凝血活酶时间(aPTT)以识别因使用抗凝剂导致凝血障碍犬只的能力。

地点

兽医教学医院。

动物

六只健康成年犬,为现有研究群体的一部分。一只犬未纳入华法林部分的研究。

测量与主要结果

给予普通肝素(UFH,静脉注射50 U/kg一次,然后皮下注射300 U/kg,每8小时一次)以延长aPTT。用枸橼酸盐全血通过VSPro进行PT和aPTT分析,并重复检测。将VSPro的结果与用标准台式凝血仪(AMAX Destiny)检测血浆中的PT和aPTT结果进行比较。随后有至少24小时的洗脱期。一旦犬只的PT和aPTT值正常,给予华法林(口服0.25 - 0.30 mg/kg一次,然后根据需要每12小时口服0.15 mg/kg)以延长PT值。共评估了70份用于PT检测的样本和73份用于aPTT检测的样本。VSPro重复检测PT和aPTT的Pearson相关系数(PCC)分别为0.941和0.891(P < 0.001)。VSPro与AMAX之间PT的PCC为0.578,aPTT的PCC为0.865(P < 0.001)。受试者工作特征(ROC)分析表明,VSPro PT值为21.6秒时诊断凝血障碍(依据AMAX)的最大灵敏度和特异性分别为72%和86%,VSPro aPTT为105.3秒时最大灵敏度和特异性分别为93%和89%。PT和aPTT的阳性预测值分别为84%和89%。

结论

Abaxis VSPro与临床实验室检测显示出可接受的相关性,是用于识别PT或aPTT异常动物的有用即时检验设备。