Suppr超能文献

建立一种侧向流荧光微球免疫分析方法用于牛奶中磺胺嘧啶的测定。

Development of a lateral flow fluorescent microsphere immunoassay for the determination of sulfamethazine in milk.

机构信息

College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, Beijing Laboratory for Food Quality and Safety, Beijing, 100193, China.

出版信息

Anal Bioanal Chem. 2013 Aug;405(21):6783-9. doi: 10.1007/s00216-013-7150-4. Epub 2013 Jul 9.

Abstract

The fluorescent microsphere has been increasingly used as detecting label in immunoassay because of its stable configuration, high fluorescence intensity, and photostability. In this paper, we developed a novel lateral flow fluorescent microsphere immunoassay (FMIA) for the determination of sulfamethazine (SMZ) in milk in a quantitative manner with high sensitivity, selectivity, and rapidity. A monoclonal antibody to SMZ was covalently conjugated with the carboxylate-modified fluorescent microsphere, which is polystyrene with a diameter of 200 nm. Quantitative detection of SMZ in milk was accomplished by recording the fluorescence intensity of microspheres captured on the test line after the milk samples were diluted five times. Under optimal conditions, the FMIA displays a rapid response for SMZ with a limit of detection of as low as 0.025 ng mL(-1) in buffer and 0.11 μg L(-1) in milk samples. The FMIA was then successfully applied on spiked milk samples and the recoveries ranged from 101.1 to 113.6% in the inter-batch assay with coefficient of variations of 6.0 to 14.3%. We demonstrate here that the fluorescent microsphere-based lateral flow immunoassay (LFIA) is capable of rapid, sensitive, and quantitative detection of SMZ in milk.

摘要

荧光微球由于其结构稳定、荧光强度高、光稳定性好,已越来越多地被用作免疫分析中的检测标记物。本文建立了一种新型的侧向流荧光微球免疫分析(FMIA)方法,用于定量检测牛奶中的磺胺甲噁唑(SMZ),该方法具有高灵敏度、选择性和快速的特点。将针对 SMZ 的单克隆抗体与羧基化修饰的荧光微球共价偶联,该微球的直径为 200nm,为聚苯乙烯微球。通过记录牛奶样品经五倍稀释后在检测线上捕获的微球的荧光强度,实现对牛奶中 SMZ 的定量检测。在最佳条件下,FMIA 对 SMZ 的快速响应,在缓冲液中的检测限低至 0.025ng mL(-1),在牛奶样品中的检测限低至 0.11μg L(-1)。然后,该方法成功地应用于添加牛奶样品的检测,在批间测定中回收率范围为 101.1%至 113.6%,变异系数为 6.0%至 14.3%。本研究表明,基于荧光微球的侧向流免疫分析(LFIA)能够快速、灵敏、定量地检测牛奶中的 SMZ。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验