This study aimed to evaluate the diagnostic value of SonoLiver software for parametric imaging in breast tumors.
Contrast-enhanced ultrasound (CEUS) was performed in 216 breast lesions (113 malignant, 103 benign). The CEUS parameters were compared between benign and malignant lesions. The rise time, the time to peak, the mean transit time and dynamic vessel pattern (DVP) were analyzed using SonoLiver software.
Quantitative analysis showed that the rise time was 16.52±4.15 seconds in the benign group vs. 13.86±3.36 seconds in the malignant group (p=0.007), and the time to peak was 19.86±4.87 seconds in the benign group vs. 16.52±4.85 seconds in the malignant group (p=0.009). The mean transit time was 80.55±18.65 seconds in the benign group vs. 65.16±20.28 seconds in the malignant group (p=0.006). The difference between the distribution of DVP in benign and malignant tumors was statistically significant. One hundred one malignant tumors (89.4%) performed an irregular red/yellow fill in the region of interest (ROI) and 85 benign tumors (82.5%) performed a single blue/green fill in the ROI. The sensitivity, specificity, and accuracy of parametric imaging in breast tumors were 84.1%, 85.4%, 84.7%, respectively.
The CEUS parametric imaging can distinguish differences between malignant and benign breast tumors as well as provide diagnostic information on breast lesions.
本研究旨在评估 SonoLiver 软件在乳腺肿瘤参数成像中的诊断价值。
对 216 个乳腺病变(113 个恶性,103 个良性)进行了对比增强超声(CEUS)检查。比较了良性和恶性病变之间的 CEUS 参数。使用 SonoLiver 软件分析了上升时间、达峰时间、平均渡越时间和动态血管模式(DVP)。
定量分析显示,良性组的上升时间为 16.52±4.15 秒,恶性组为 13.86±3.36 秒(p=0.007),达峰时间良性组为 19.86±4.87 秒,恶性组为 16.52±4.85 秒(p=0.009)。良性组的平均渡越时间为 80.55±18.65 秒,恶性组为 65.16±20.28 秒(p=0.006)。良性和恶性肿瘤 DVP 分布的差异具有统计学意义。101 个恶性肿瘤(89.4%)在感兴趣区(ROI)呈不规则的红/黄填充,85 个良性肿瘤(82.5%)在 ROI 呈单一的蓝/绿填充。乳腺肿瘤参数成像的灵敏度、特异度和准确度分别为 84.1%、85.4%和 84.7%。
CEUS 参数成像可以区分乳腺良恶性肿瘤,为乳腺病变提供诊断信息。