Willy Taillard Laboratory of Kinesiology, Geneva University Hospitals and Faculty of Medicine, Switzerland.
Gait Posture. 2014 Jan;39(1):147-53. doi: 10.1016/j.gaitpost.2013.06.016. Epub 2013 Jul 10.
Although, several thorax models have been proposed for clinical gait analysis, none has received widespread acceptance nor been subject to any extensive validation work, especially for the marker set to use. The aim of this study was thus to determine the optimal and minimal makers' placement on the thorax for clinical gait analysis. Ten healthy subjects have performed a series of movements (arm, head, trunk) with large amplitude during walking. Reflective markers were taped on the thorax (C7, T2, T4, T6, T8, T10, T12, sternum, clavicles and ribs) and their 3D positions were captured with an opto-electronic system. Each combination of 3 markers has been tested. The global error of each model was computed with the estimated position of the markers considering the thorax segment as a solid segment. Two families of marker sets were identified with the lowest error. The first family was composed by two anterior and one posterior marker on the thorax (incisura jugularis (IJ), xiphoid process, and T8). The second family was composed by two posterior and one anterior maker (IJ, T2 and T8 or T10). Even, if these two families of marker sets presented a similar error for marker position, the angles obtained from these marker sets showed large differences especially for the axial rotation movement of the trunk (up to 40.1°). The optimal and minimal maker set identified with a variety of large movements of the trunk, head and arms was IJ, T2 and T8 or T10.
虽然已经提出了几种用于临床步态分析的胸廓模型,但没有一种得到广泛认可,也没有经过任何广泛的验证工作,特别是对于要使用的标记集。因此,本研究旨在确定用于临床步态分析的胸廓上最佳和最小标记放置位置。 10 名健康受试者在行走时进行了一系列大振幅的运动(手臂、头部、躯干)。在胸廓上贴上反射标记(C7、T2、T4、T6、T8、T10、T12、胸骨、锁骨和肋骨),并使用光电系统捕获其 3D 位置。测试了每个 3 个标记的组合。通过考虑胸廓为固体段,计算了每个模型的全局误差。确定了两个具有最低误差的标记集族。第一个家族由胸廓上的两个前标记和一个后标记组成(颈静脉切迹(IJ)、剑突和 T8)。第二个家族由两个后标记和一个前标记组成(IJ、T2 和 T8 或 T10)。即使这两个标记集族的标记位置具有相似的误差,但这些标记集获得的角度差异很大,特别是对于躯干的轴向旋转运动(最大可达 40.1°)。使用各种躯干、头部和手臂的大运动确定了最佳和最小的标记集,即 IJ、T2 和 T8 或 T10。