Division of Viral Diseases, Gastroenteritis and Respiratory Viruses Laboratory Branch, Centers for Disease Control and Prevention, Atlanta, GA, USA.
J Clin Virol. 2013 Sep;58(1):292-4. doi: 10.1016/j.jcv.2013.06.022. Epub 2013 Jul 10.
Rotaviruses are the major cause of severe dehydrating diarrhea in children throughout the world. Enzyme immunoassays (EIAs) have been the standard method for detection of rotavirus in stool specimens since the 1980s. The World Health Organization (WHO) Rotavirus Surveillance Network has proposed including three EIA kits in the WHO-GSM (Global Management System/Système Mondial de Gestion) catalog for easy procurement of EIA kits by participating rotavirus surveillance network laboratories.
In this study, we conducted a comparative analysis of 3 commercially available enzyme immunoassay kits: Premier™ Rotaclone® (Meridian Bioscience, Inc.), ProSpecT™ (Oxoid, Ltd.) and RIDASCREEN® (R-biopharm AG) for rotavirus diagnostics.
Using reverse-transcriptase-PCR (RT-PCR) as the gold standard, the 3 EIA kits were evaluated by testing a stool panel consisting of 56 rotavirus-positive and 54 rotavirus negative samples.
The sensitivities of the Premier™ Rotaclone®, ProSpecT™ and RIDASCREEN® kits were 76.8%, 75% and 82.1%, respectively, but did not differ significantly. The specificity of all the 3 kits was 100%. The use of RT-PCR as a gold standard lowered the observed sensitivity of all 3 EIA kits but helps to reduce equivocal results that can be seen when another EIA or other non-molecular methods are used as the reference assay in comparison studies.
Our study found that all three kits are suitable for use by rotavirus surveillance programs.
轮状病毒是全球儿童严重腹泻脱水的主要原因。自 20 世纪 80 年代以来,酶免疫测定(EIA)已成为检测粪便标本中轮状病毒的标准方法。世界卫生组织(WHO)轮状病毒监测网络已提议在 WHO-GSM(全球管理系统/管理系统 Mondial)目录中包含三种 EIA 试剂盒,以便参与轮状病毒监测网络实验室能够方便地采购 EIA 试剂盒。
在本研究中,我们对三种市售酶免疫测定试剂盒进行了比较分析:Premier™ Rotaclone®(Meridian Bioscience,Inc.)、ProSpecT™(Oxoid,Ltd.)和 RIDASCREEN®(R-biopharm AG),用于轮状病毒诊断。
使用逆转录-聚合酶链反应(RT-PCR)作为金标准,通过测试由 56 份轮状病毒阳性和 54 份轮状病毒阴性样本组成的粪便样本进行了 3 种 EIA 试剂盒的评估。
Premier™ Rotaclone®、ProSpecT™和 RIDASCREEN®试剂盒的敏感性分别为 76.8%、75%和 82.1%,但无显著差异。三种试剂盒的特异性均为 100%。使用 RT-PCR 作为金标准降低了所有三种 EIA 试剂盒的观察敏感性,但有助于减少在比较研究中使用另一种 EIA 或其他非分子方法作为参考测定时可能出现的不确定结果。
我们的研究发现,所有三种试剂盒都适合轮状病毒监测计划使用。