Suppr超能文献

乳腺钼靶摄影和超声检查联合BI-RADS评估在18F-FDG PET-CT上对乳腺偶然发现的代谢增高性病变评估中的作用

Role of combined BI-RADS assessment using mammography and sonography for evaluation of incidental hypermetabolic lesions in the breast on 18F-FDG PET-CT.

作者信息

Lim Soyeoun, Lee Eun Hye, Park Jung Mi, Chang Yon-Woo, Kim Hyung Hwan, Jeong Sun Hye

机构信息

Department of Radiology, Soonchunhyang University Bucheon Hospital, Gyeonggi-do, Republic of Korea.

出版信息

Acta Radiol. 2013 Dec;54(10):1117-24. doi: 10.1177/0284185113492453. Epub 2013 Jul 17.

Abstract

BACKGROUND

PET-CT is widely used for evaluation and follow-up of malignancy. Incidental hypermetabolic lesions are often found on PET-CT, some of which are confirmed to be malignant.

PURPOSE

To estimate the role of combined Breast Imaging-Reporting and Data System (BI-RADS) assessment using mammography and sonography for evaluation of incidental hypermetabolic lesions on 18F-FDG PET-CT and to determine an appropriate next step.

MATERIAL AND METHODS

This study included incidental hypermetabolic lesions found in the breasts of 7594 women who underwent PET-CT at three university-affiliated hospitals between January 2006 and December 2011. We reviewed the maximum standardized uptake value (SUVmax) of incidental lesions, combined BI-RADS assessment of mammography and sonography, and final results. We analyzed the negative predictive values of the probably benign (categories 1-3) group and the sensitivity of suspicious (categories 4 and 5) groups according to combined BI-RADS assessment.

RESULTS

Forty-three patients (0.6%) had 49 incidental hypermetabolic lesions in the breast. Histologic diagnosis in 17 patients confirmed nine breast cancers (27.3%). Sixteen patients underwent imaging follow-up for at least 2 years; no breast cancer was detected. Thirteen patients were lost to follow-up and were excluded. For the suspicious (n = 14) and probably benign (n = 19) groups according to combined BI-RADS assessment, both the sensitivity and negative predictive values were 100%. Using an optimal diagnostic cut-off value of 2.15, the malignancy rate was not significantly different (16.7% vs. 45.5%, respectively, in the group with SUVmax < 2.15 and the group with SUVmax ≥ 2.15; P > 0.05). The SUVmax of the confirmed malignant and assumed benign groups were not significantly different (3.1% vs. 2.2%, respectively; P > 0.05).

CONCLUSION

Both mammography and sonography should be considered the next step to evaluate incidental hypermetabolic lesions on 18F-FDG PET-CT because combined BI-RADS assessment provides an excellent negative predictive value for excluding malignancy.

摘要

背景

正电子发射断层显像-计算机断层扫描(PET-CT)广泛用于恶性肿瘤的评估及随访。PET-CT上常发现偶然的高代谢病变,其中一些经证实为恶性。

目的

评估乳腺影像报告和数据系统(BI-RADS)联合乳腺钼靶和超声检查在评估18F-FDG PET-CT上偶然发现的高代谢病变中的作用,并确定合适的下一步检查。

材料与方法

本研究纳入了2006年1月至2011年12月期间在三家大学附属医院接受PET-CT检查的7594名女性乳房中偶然发现的高代谢病变。我们回顾了偶然病变的最大标准化摄取值(SUVmax)、乳腺钼靶和超声的联合BI-RADS评估以及最终结果。我们根据联合BI-RADS评估分析了可能为良性(1-3类)组的阴性预测值和可疑(4类和5类)组的敏感性。

结果

43例患者(0.6%)乳房中有49个偶然的高代谢病变。17例患者的组织学诊断证实为9例乳腺癌(27.3%)。16例患者接受了至少2年的影像随访;未检测到乳腺癌。13例患者失访并被排除。根据联合BI-RADS评估,可疑组(n = 14)和可能为良性组(n = 19)的敏感性和阴性预测值均为100%。使用2.15的最佳诊断临界值,恶性率无显著差异(SUVmax < 2.15组和SUVmax≥2.15组分别为16.7%和45.5%;P>0.05)。确诊为恶性组和假定为良性组的SUVmax无显著差异(分别为3.1%和2.2%;P>0.05)。

结论

乳腺钼靶和超声均应被视为评估18F-FDG PET-CT上偶然发现的高代谢病变的下一步检查,因为联合BI-RADS评估在排除恶性肿瘤方面具有出色的阴性预测值。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验