Abstract

Occupational exposure to non-ionising electromagnetic radiation emitted by train protection (TP) systems operating at ∼27 MHz is investigated in situ. In total, five TP systems of two different types, i.e. KVB (Contrôle de Vitesse par Balises) and TBL1+ (Transmission Balise-Locomotive), are considered. For each type, the boundaries outside which the field levels are in compliance with the International Commission on Non-Ionizing Radiation Protection guidelines for occupational exposure ('compliance boundaries') are determined. Maximal fields of 4.7 A m(-1) and 0.2 kV m(-1) for KVB, and 51 A m(-1) and 1.5 kV m(-1) for TBL1+ are measured, at distances between 10 and 25 cm from the respective antennas. Compliance boundaries for occupational exposure are maximally 0.6 m for KVB to 1 m for TBL1+, while no specific compliance boundary is needed for the general public.