Tian Qing-Wu, Xuan Chao, Wang Hong-Wei, Zhao Jin-Xia, Yu Wei-Lin, Gao Ge, Zhang Bei-Bei, Lun Li-min
Department of Clinical Laboratory, The Affiliated Hospital of Medical College, Qingdao University, Qingdao, China.
Genet Test Mol Biomarkers. 2013 Sep;17(9):687-95. doi: 10.1089/gtmb.2013.0099. Epub 2013 Jul 23.
The accuracy of glycosylated hemoglobin (HBA1c) detection for the diagnosis of gestational diabetes mellitus (GDM) has been extensively studied in the Chinese population, but the exact role of these detections remains controversial. The present meta-analysis was performed to establish the overall accuracy of HBA1c for the diagnosis of Chinese patients with GDM.
After a systematic review of related studies, the sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and other measures about the accuracy of HBA1c in the diagnosis of GDM were pooled using random-effects models. The summary receiver operating characteristic (SROC) curve analysis was used to summarize the overall test performance.
Forty-one studies included 2812 Chinese patients with GDM and 5918 controls were included in our meta-analysis. The summary estimates for HBA1c in the diagnosis of GDM in the studies included were as follows: sensitivity 0.762 (95% confidence interval [CI]: 0.746-0.777), specificity 0.917 (95% CI: 0.910-0.924), PLR 8.21 (95% CI: 3.77-17.89), NLR 0.20 (95% CI: 0.09-0.44), and DOR 41.40 (95% CI: 11.47-149.38). Our data showed that the SROC curve is positioned near the desirable upper left corner of the SROC curve, while the area under curve (AUC) was 0.93 with a Q* value of 0.865.
Measurement of HBA1c is likely to be a useful diagnostic tool for confirming GDM. The results of HBA1c should be interpreted in parallel with clinical findings and the results of conventional tests.
糖化血红蛋白(HBA1c)检测用于诊断妊娠期糖尿病(GDM)的准确性已在中国人群中得到广泛研究,但这些检测的确切作用仍存在争议。本荟萃分析旨在确定HBA1c诊断中国GDM患者的总体准确性。
在对相关研究进行系统回顾后,使用随机效应模型汇总了HBA1c诊断GDM准确性的敏感性、特异性、阳性似然比(PLR)、阴性似然比(NLR)、诊断比值比(DOR)及其他指标。采用汇总受试者工作特征(SROC)曲线分析来总结总体检测性能。
41项研究纳入了2812例中国GDM患者和5918例对照,纳入研究中HBA1c诊断GDM的汇总估计值如下:敏感性0.762(95%置信区间[CI]:0.746 - 0.777),特异性0.917(95%CI:0.910 - 0.924),PLR 8.21(95%CI:3.77 - 17.89),NLR 0.20(95%CI:0.09 - 0.44),DOR 41.40(95%CI:11.47 - 149.38)。我们的数据显示SROC曲线位于理想的SROC曲线左上角附近,曲线下面积(AUC)为0.93,Q*值为0.865。
检测HBA1c可能是确诊GDM的有用诊断工具。HBA1c的结果应与临床发现及传统检测结果综合解读。