Department of Neurology and Neurotherapeutics, University of Texas Southwestern Medical Center, 5323 Harry Hives Blvd, Dallas, TX, 75390-9129, USA,
Clin Auton Res. 2013 Dec;23(6):297-303. doi: 10.1007/s10286-013-0209-7. Epub 2013 Jul 24.
To determine normal values for pupillometry indices in healthy control subjects and to examine these indices in patients with autonomic dysfunction and healthy controls.
Infrared video pupillometry was used to investigate the pupil response to a brief light flash in 79 healthy controls, 28 patients with normal autonomic function (composite autonomic severity score, CASS < 2), and 26 patients with moderate to severe autonomic failure (CASS > 4) seen in our autonomic laboratory from January 2008 to June 2011. In six subjects, we examined the effects of varying light stimulus intensity and light stimulus duration. Descriptive analysis, correlation, and ANCOVA adjusted for age were performed.
We determined eight indices corresponding to parasympathetic and sympathetic pupil function. Baseline pupil diameter (BPD), maximum constriction velocity (MCV), absolute constriction amplitude (ACA), and maximum dilation velocity (MDV) negatively correlated with age (p < 0.01) among controls. MCV and ACA increased with increasing intensity of light stimulus from 3.5 to 112 μW. Indices of parasympathetic pupil innervation (MCV and ACA) were lower in the high CASS group compared to others (p < 0.0001). Indices of sympathetic pupil function, time to reach 75 % of initial resting diameter during pupillary dilation (T¾), and dilation velocity at T¾ (DV¾) did not differ significantly in the three study groups. However, T¾ corrected for the magnitude of pupillary constriction (T¾:ACA) was higher in the high CASS group suggesting sympathetic dysfunction in that group (p = 0.0003).
Indices of pupillomotor function significantly differ between patients with moderate to severe autonomic failure and healthy controls.
确定健康对照者瞳孔测量指标的正常值,并检查自主神经功能障碍患者和健康对照者的这些指标。
使用红外视频瞳孔测量法,对 2008 年 1 月至 2011 年 6 月在我们的自主神经实验室就诊的 79 名健康对照者、28 名自主神经功能正常(综合自主严重程度评分,CASS<2)和 26 名中重度自主衰竭(CASS>4)患者的瞳孔对短暂光闪烁的反应进行了研究。在 6 名受试者中,我们检查了不同光刺激强度和光刺激持续时间的影响。进行了描述性分析、相关性分析和协方差分析(调整年龄)。
我们确定了对应于副交感和交感瞳孔功能的 8 个指标。在对照组中,基础瞳孔直径(BPD)、最大收缩速度(MCV)、绝对收缩幅度(ACA)和最大扩张速度(MDV)与年龄呈负相关(p<0.01)。随着光刺激强度从 3.5 到 112 μW 的增加,MCV 和 ACA 增加。与其他组相比,高 CASS 组的副交感瞳孔支配(MCV 和 ACA)指数较低(p<0.0001)。交感瞳孔功能指标、瞳孔扩张时达到初始静止直径 75%的时间(T¾)和 T¾时的扩张速度(DV¾)在三组研究对象中差异无统计学意义。然而,校正瞳孔收缩幅度后的 T¾(T¾:ACA)在高 CASS 组中较高,提示该组存在交感神经功能障碍(p=0.0003)。
中重度自主衰竭患者与健康对照者的瞳孔运动功能指标有显著差异。