Suppr超能文献

动作电位时程与舒张功能障碍在转基因和药物诱导的长 QT2 兔中的空间相关性。

Spatial correlation of action potential duration and diastolic dysfunction in transgenic and drug-induced LQT2 rabbits.

机构信息

Department of Cardiology and Angiology I, Heart Center Freiburg University, Freiburg, Germany.

出版信息

Heart Rhythm. 2013 Oct;10(10):1533-41. doi: 10.1016/j.hrthm.2013.07.038. Epub 2013 Jul 26.

Abstract

BACKGROUND

Enhanced dispersion of action potential duration (APD) is a major contributor to long QT syndrome (LQTS)-related arrhythmias.

OBJECTIVE

To investigate spatial correlations of regional heterogeneities in cardiac repolarization and mechanical function in LQTS.

METHODS

Female transgenic LQTS type 2 (LQT2; n = 11) and wild-type littermate control (LMC) rabbits (n = 9 without E4031 and n = 10 with E4031) were subjected to phase contrast magnetic resonance imaging to assess regional myocardial velocities. In the same rabbits' hearts, monophasic APDs were assessed in corresponding segments.

RESULTS

In LQT2 and E4031-treated rabbits, APD was longer in all left ventricular segments (P < .01) and APD dispersion was greater than that in LMC rabbits (P < .01). In diastole, peak radial velocities (Vr) were reduced in LQT2 and E4031-treated compared to LMC rabbits in LV base and mid (LQT2: -3.36 ± 0.4 cm/s, P < .01; E4031-treated: -3.24 ± 0.6 cm/s, P < .0001; LMC: -4.42 ± 0.5 cm/s), indicating an impaired diastolic function. Regionally heterogeneous diastolic Vr correlated with APD (LQT2: correlation coefficient [CC] 0.38, P = .01; E4031-treated: CC 0.42, P < .05). Time-to-diastolic peak Vr were prolonged in LQT2 rabbits (LQT2: 196.8 ± 2.9 ms, P < .001; E4031-treated: 199.5 ± 2.2 ms, P < .0001, LMC 183.1 ± 1.5), indicating a prolonged contraction duration. Moreover, in transgenic LQT2 rabbits, diastolic time-to-diastolic peak Vr correlated with APD (CC 0.47, P = .001). In systole, peak Vr were reduced in LQT2 and E4031-treated rabbits (P < .01) but longitudinal velocities or ejection fraction did not differ. Finally, random forest machine learning algorithms enabled a differentiation between LQT2, E4031-treated, and LMC rabbits solely based on "mechanical" magnetic resonance imaging data.

CONCLUSIONS

The prolongation of APD led to impaired diastolic and systolic function in transgenic and drug-induced LQT2 rabbits. APD correlated with regional diastolic dysfunction, indicating that LQTS is not purely an electrical but an electromechanical disorder.

摘要

背景

动作电位时程(APD)的增强离散是长 QT 综合征(LQTS)相关心律失常的主要原因。

目的

研究 LQTS 中心脏复极和机械功能的区域性异质性的空间相关性。

方法

雌性转基因 LQT2(LQT2;n = 11)和野生型同窝对照(LMC)兔(n = 9 无 E4031 和 n = 10 用 E4031)接受相位对比磁共振成像以评估局部心肌速度。在相同的兔子心脏中,评估相应节段的单相 APD。

结果

在 LQT2 和 E4031 处理的兔子中,所有左心室节段的 APD 均较长(P <.01),并且 APD 离散度大于 LMC 兔子(P <.01)。在舒张期,与 LMC 兔子相比,LQT2 和 E4031 处理的兔子的 LV 基底部和中部的峰值径向速度(Vr)降低(LQT2:-3.36 ± 0.4 cm/s,P <.01;E4031 处理:-3.24 ± 0.6 cm/s,P <.0001;LMC:-4.42 ± 0.5 cm/s),表明舒张功能受损。区域性异质舒张 Vr 与 APD 相关(LQT2:相关系数[CC] 0.38,P =.01;E4031 处理:CC 0.42,P <.05)。LQT2 兔的舒张期至舒张期峰值 Vr 时间延长(LQT2:196.8 ± 2.9 ms,P <.001;E4031 处理:199.5 ± 2.2 ms,P <.0001,LMC 183.1 ± 1.5 ms),表明收缩持续时间延长。此外,在转基因 LQT2 兔中,舒张期时间至舒张期峰值 Vr 与 APD 相关(CC 0.47,P =.001)。在收缩期,LQT2 和 E4031 处理的兔子的 Vr 峰值降低(P <.01),但纵向速度或射血分数没有差异。最后,随机森林机器学习算法能够仅基于“机械”磁共振成像数据区分 LQT2、E4031 处理和 LMC 兔子。

结论

APD 的延长导致转基因和药物诱导的 LQT2 兔子舒张和收缩功能受损。APD 与区域性舒张功能障碍相关,表明 LQTS 不仅是电异常,而且是机电异常。