Suppr超能文献

植入新型有晶状体眼人工晶状体后白内障手术的视觉和屈光结果

Visual and refractive outcomes after cataract surgery with implantation of a new toric intraocular lens.

作者信息

Mazzini Cinzia

机构信息

Clinica Oculistica, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy.

出版信息

Case Rep Ophthalmol. 2013 Jun 27;4(2):48-56. doi: 10.1159/000353389. Print 2013 May.

Abstract

PURPOSE

The aim of this study was to evaluate and report the visual, refractive and aberrometric outcomes of cataract surgery with implantation of the new aspheric Tecnis ZCT toric intraocular lens (IOL) in eyes with low to moderate corneal astigmatism.

METHODS

We conducted a prospective study of 19 consecutive eyes of 17 patients (mean age: 78 years) with a visually significant cataract and moderate corneal astigmatism [higher than 1 diopter (D)] undergoing cataract surgery with implantation of the aspheric Tecnis ZCT toric IOL (Abbott Medical Optics). Visual, refractive and aberrometric changes were evaluated during a 6-month follow-up. Ocular aberrations as well as IOL rotation were evaluated by means of the OPD-Station II (Nidek).

RESULTS

The six-month postoperative spherical equivalent and power vector components of the refractive cylinder were within ±0.50 D in all eyes (100%). Postoperative logMAR uncorrected and corrected distance visual acuities (UDVA/CDVA) were 0.1 (about 20/25) or better in almost all eyes (94.74%). The mean logMAR CDVA improved significantly from 0.41 ± 0.23 to 0.02 ± 0.05 (p < 0.01). No significant changes were found in corneal astigmatism (p = 0.73). The mean IOL rotation was 3.33 ± 1.94°. This parameter did not correlate with higher-order aberrations (r = -0.09, p = 0.73). A significant improvement in the Strehl ratio was also observed (p < 0.01), which was consistent with the significant reduction in higher-order aberrations (p = 0.02).

CONCLUSION

Cataract surgery with implantation of the aspheric Tecnis ZCT IOL is a predictable and effective procedure for visual rehabilitation in eyes with cataract and low to moderate corneal astigmatism, providing an excellent postoperative ocular optical quality.

摘要

目的

本研究旨在评估并报告在低至中度角膜散光眼中植入新型非球面Tecnis ZCT散光型人工晶状体(IOL)的白内障手术的视觉、屈光和像差结果。

方法

我们对17例(平均年龄:78岁)患有具有视觉意义的白内障和中度角膜散光[高于1屈光度(D)]的患者的19只连续眼睛进行了一项前瞻性研究,这些患者接受了植入非球面Tecnis ZCT散光型IOL(雅培医疗光学公司)的白内障手术。在6个月的随访期间评估视觉、屈光和像差变化。通过OPD-Station II(尼德克)评估眼像差以及IOL旋转。

结果

所有眼睛(100%)术后6个月的等效球镜度和屈光柱镜的屈光力矢量分量均在±0.50 D以内。几乎所有眼睛(94.74%)术后logMAR未矫正和矫正远视力(UDVA/CDVA)为0.1(约20/25)或更好。平均logMAR CDVA从0.41±0.23显著提高至0.02±0.05(p<0.01)。角膜散光无显著变化(p = 0.73)。平均IOL旋转为3.33±1.94°。该参数与高阶像差无相关性(r = -0.09,p = 0.73)。还观察到斯特列尔比有显著改善(p<0.01),这与高阶像差的显著降低一致(p = 0.02)。

结论

植入非球面Tecnis ZCT IOL的白内障手术是一种可预测且有效的手术,用于白内障和低至中度角膜散光眼的视觉康复,可提供优异的术后眼光学质量。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/135a/3724128/58a0ae099b14/cop-0004-0048-g01.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验